Schneider LG1K065Q707A37 TeSys LG Enclosed DOL Starter

MPNLG1K065Q707A37
Active

Schneider Electric TeSys LG series, LG1K065Q707A37 enclosed DOL starter, thermal protection 1.6-2.5 A, 380/400 V AC 50/60 Hz coil, IP55, polycarbonate enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG1K065Q707A37 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth165 mm

Product details

What this enclosed DOL starter packs

The Schneider LG1K065Q707A37 is a TeSys LG enclosed direct-on-line starter rated for safety applications — it bundles a contactor, a switch-disconnector, and a circuit-breaker into one IP55 polycarbonate box, so you get motor starting, isolation, and short-circuit protection in a single SKU. The thermal protection adjustment range is 1.6 to 2.5 A, which sets the overload relay trip point for the motor full-load current. In AC-3 duty (squirrel-cage motors) this covers 0.37 kW at 220/230 V AC and 0.75 kW at 400/415 V AC, or 1.1 kW at 440 V AC.

What's on the front panel

The enclosure face carries a white push-button for start, a black push-button for stop, a red rotary-handle emergency stop, and a red mushroom-head emergency stop push-button. That gives you both a maintained E-stop (rotary latch) and a momentary E-stop on the same door. Cable entries are pre-punched: four knockouts total — two Pg 13 and two Pg 16 on top, same pattern on the bottom. That's enough for incoming power, motor leads, and control wiring without drilling.

Standards and lifecycle

Frequently asked questions

Does LG1K065Q707A37 include a circuit breaker and emergency stop?

Yes. The LG1K065Q707A37 includes a circuit-breaker, a switch-disconnector, a contactor, a rotary-handle emergency stop (red), and a mushroom-head push-button emergency stop (red), all factory-integrated in the enclosure.

Is LG1K065Q707A37 suitable for a 0.37 kW motor?

Yes. The thermal protection range of 1.6 to 2.5 A covers a 0.37 kW motor at 220/230 V AC (AC-3 duty). It also covers 0.75 kW at 400/415 V AC and 1.1 kW at 440 V AC.

What is the difference between LG1K065Q707A37 and LG1K065Q707A36?

The difference is in the coil voltage. The LG1K065Q707A37 has a 380/400 V AC coil, while the LG1K065Q707A36 uses a different control voltage. All other ratings (thermal range, enclosure, internal composition) are identical.