Skip to main content
Schneider Electric LG1K095M714 — Motor Starters

TeSys LG1K095M714 Enclosed DOL Starter, 4 kW, Obsolete

MPNLG1K095M714
Obsolete

TeSys LG, enclosed DOL starter, LG1K095M714, 4 kW at 400/415 V AC, 6-10 A thermal protection, 220/230 V AC coil, IP55.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG1K095M714 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth165 mm

Product details

The TeSys LG1K095M714 is an enclosed direct-on-line (DOL) starter from the TeSys LG range, integrating a contactor, switch disconnector, and circuit-breaker in a single IP55 polycarbonate enclosure rated IK07. Rated for 4 kW motor loads at 400/415 V AC 50/60 Hz (AC-3 utilisation category), it includes a thermal protection adjustment range of 6...10 A and a 220/230 V AC control circuit coil. The front panel carries a white push-button start, a black push-button stop, and a red rotary emergency stop handle — a self-contained safety solution for a single motor branch.

The LG1K095M714 is classified as obsolete by the manufacturer.

The 4 kW rating at 400/415 V AC in AC-3 duty means this starter switches standard three-phase squirrel-cage induction motors up to that power — the AC-3 category covers starting and switching off running motors, not resistive loads. The thermal protection adjustment range of 6...10 A sets the overload relay trip point; set it to the motor's full-load current, not the starter's maximum, to avoid nuisance tripping or inadequate protection. IP55 and IK07 mean the enclosure is dust-protected and withstands water jets from any direction plus 0.5 J impact — suitable for washdown areas or outdoor installation where hose-down cleaning is routine. Dimensions of 165 mm depth, 175 mm width, and 165 mm height (polycarbonate) determine the gland-plate layout and DIN-rail or back-panel footprint; the cable entries (4 x Pg13 + 2 x Pg16 top and bottom) dictate conduit or cable-gland sizing.

Frequently asked questions

Is LG1K095M714 obsolete?

Yes, the LG1K095M714 is classified as obsolete by the manufacturer. It is sourced to order against an RFQ through independent distribution; availability and pricing are confirmed at quote time.

Does LG1K095M714 include a circuit breaker?

Yes, the LG1K095M714 integrates a circuit-breaker as part of its device composition, along with a contactor and switch disconnector, in a single enclosed DOL starter unit.

What is the difference between LG1K095M714 and LG1K091M714?

The primary difference is the thermal protection adjustment range: the LG1K095M714 covers 6...10 A, while the LG1K091M714 covers a different range. Both are enclosed DOL starters in the TeSys LG family with the same IP55 enclosure and control voltage options.

MPN
LG1K095M714