Schneider Electric LG7D18M7 — Motor Starters

TeSys LG7D18M7 Enclosed DOL Starter, 18 A AC-3

MPNLG7D18M7
Obsolete

Schneider Electric TeSys LG enclosed DOL starter, 18 A AC-3, 220 V AC 50/60 Hz coil, IP55, IK07, polycarbonate enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG7D18M7 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth146 mm

Product details

The enclosure is polycarbonate with an IP55 rating, so it handles washdown splashes and dust ingress in industrial environments, and an IK07 impact rating means it resists mechanical shocks up to 2 J. Cable entries are 4 x Pg 13 plus 2 x Pg 16 on both top and bottom faces — no extra gland plate needed for a standard motor and control cable run. The front panel carries a white push-button for start (I), a black push-button for stop (O), and a red mushroom-head push-button for emergency stop — the kit is complete for local motor control without adding pilot devices.

Because this is a discontinued enclosed starter, the buyer's decision hinges on whether the BOM can accept the original part or must migrate. If the line is down and the replacement path is already qualified, the surplus channel is the fastest route; if the design can flex, the official successor (if one exists) avoids future obsolescence risk.

The LG7D18M7 ships as a complete enclosed DOL starter: polycarbonate enclosure with the contactor and control station integrated. What does not ship inside the box is the circuit breaker — the device composition states the circuit breaker is ordered separately, so the kit has a hole in it unless you add the matching breaker to the order. The contactor is included. Dimensions are 175 mm wide by 165 mm high by 146 mm deep — fits standard 200 mm enclosure backplate layouts with room for the separate breaker alongside.

Frequently asked questions

What is the replacement for LG7D18M7?

Schneider Electric has not published a direct official successor order code in the available lifecycle data for this part. For a drop-in replacement, the best path is to supply the full BOM context (motor rating, voltage, enclosure requirements) to a sourcing specialist who can cross-reference the TeSys LG family's current enclosed starter line.

Where can I buy LG7D18M7?

The LG7D18M7 is sourced to order against an RFQ through independent industrial-automation distribution. Submit a request for quote to confirm current availability and pricing — no stock figures are published for this obsolete line.

Does LG7D18M7 work with a 220 V AC coil?

Yes, the control circuit voltage is rated 220 V AC at 50/60 Hz. The coil is designed for that supply.

Does LG7D18M7 include a circuit breaker?

No. The device composition states the circuit breaker is ordered separately. The contactor and the push-button control station are included in the enclosure.

What contactor and circuit breaker are compatible with LG7D18M7?

The LG7D18M7 is an integrated enclosed starter; the contactor is built in. The circuit breaker is ordered separately and should be selected to match the 18 A AC-3 motor load and the coordination type (Type 1 or Type 2) per IEC 60947-4-1. A Schneider Electric TeSys GV2 or GV3 manual motor starter is the typical match for this enclosure family, but verify the physical fit and electrical coordination against the specific motor full-load current.