Skip to main content
Schneider Electric LG7K06M7 — Motor Starters

Schneider Electric LG7K06M7 TeSys LG Enclosed DOL Starter

MPNLG7K06M7
Active

Schneider Electric TeSys LG series, LG7K06M7 enclosed DOL starter, 6 A AC-3, 220/230 V AC coil, IP55, IK07, includes contactor and circuit breaker (ordered separately), emergency stop, two pushbuttons.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG7K06M7 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth177 mm

Product details

It comes pre-assembled in a polycarbonate enclosure rated IP55 and IK07, meaning it withstands water jets and mechanical impacts typical of a factory floor or outdoor installation — suitable for standard industrial environments where dust and hose-down cleaning are routine. The unit ships with a contactor and a separate circuit breaker (ordered separately) that mounts inside the same enclosure.

The 6 A AC-3 rating is the motor-switching current — it governs the maximum full-load current of the motor this starter can handle. Cable entry is via four knockouts: two Pg 13 and two Pg 16 on both the top and bottom faces, giving flexibility for top-entry or bottom-entry wiring without drilling extra holes.

The enclosure dimensions are 175 mm wide by 165 mm high by 177 mm deep.

The contactor is pre-wired to the pushbuttons and emergency stop. Verify the thermal setting matches the motor full-load current before commissioning. The control circuit is 220/230 V AC. Cable glands are not included. Use Pg 13 or Pg 16 glands for the knockouts.

Frequently asked questions

Does LG7K06M7 include a circuit breaker?

No — the circuit breaker (GV2ME-series) is ordered separately and mounts inside the enclosure alongside the contactor. The contactor (LC1K-series) and the pushbuttons/emergency stop are included.

What is the difference between TeSys LG7K and TeSys GV?

TeSys LG is an enclosed DOL starter range — a complete assembly of contactor, circuit breaker (ordered separately), enclosure, and control devices (pushbuttons, emergency stop). TeSys GV is a manual motor starter / circuit breaker only, without the contactor or enclosure. The LG7K is a ready-to-mount motor-starting package; GV is a component you build into your own panel.

What is the wiring diagram for LG7K06M7?

The wiring diagram is part of the product datasheet. The internal wiring connects the start/stop pushbuttons to the contactor coil, the emergency stop in series with the control circuit, and the circuit breaker output to the contactor power terminals. Request the datasheet with your RFQ for the exact schematic.

MPN
LG7K06M7