Skip to main content
Schneider Electric LG7K06Q706A29 — Motor Starters

Schneider LG7K06Q706A29 TeSys LG DOL Starter, 1-1.6 A

MPNLG7K06Q706A29
Obsolete

Schneider TeSys LG enclosed DOL starter, LG7K06Q706A29, 1-1.6 A thermal protection, 380/400 V AC coil, IP55, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG7K06Q706A29 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth177 mm

Product details

The Schneider LG7K06Q706A29 is an enclosed direct-on-line (DOL) starter from the TeSys LG range, combining a contactor, circuit-breaker, and padlocking device in a single IP55 polycarbonate enclosure. Rated for AC-3 utilisation category, it switches motor loads up to 0.55 kW at 400/415 V AC and 0.25 kW at 220/230 V AC, with a thermal protection adjustment range of 1 to 1.6 A. The control circuit runs on 380/400 V AC 50/60 Hz, and the unit carries IEC 60204-1 and IEC 60947-4-1 compliance for machinery safety and motor-starter coordination.

This part is obsolete per the manufacturer's lifecycle record.

The 1 to 1.6 A thermal protection range sets the motor full-load current window — a 1.6 A setting protects a motor drawing up to that current, and the adjustment lets you fine-tune for the actual nameplate FLA. IP55 means the enclosure is dust-protected and hose-down resistant, suitable for washdown areas or outdoor installation under a canopy, but not for submersion or high-pressure jets. AC-3 duty handles starting currents and breaking the motor at standstill, the standard for squirrel-cage induction motors. Dimensions of 177 mm deep, 175 mm wide, and 165 mm high; the four cable entries (2 Pg 13 + 2 Pg 16 top and bottom) accept common metric gland sizes.

Safety application and controls

Marked for safety application, the unit includes a mushroom-head red emergency-stop pushbutton alongside the white start and black stop pushbuttons — meeting the emergency-stop requirements of IEC 60204-1 for machinery. The padlocking device on the circuit-breaker allows lockout/tagout (LOTO) isolation at the starter, which is a practical requirement for maintenance access on conveyor, pump, and fan drives.

Frequently asked questions

Is LG7K06Q706A29 obsolete?

Yes, the LG7K06Q706A29 is obsolete per the manufacturer's lifecycle record. No direct successor order code has been published, so a parametric replacement must be selected based on the same AC-3 duty, 1-1.6 A thermal protection range, and IP55 enclosure.

What is the replacement for LG7K06Q706A29?

No official successor order code is listed for the LG7K06Q706A29. The closest replacement will be another TeSys LG or TeSys GV enclosed DOL starter with the same AC-3 utilisation category, 1-1.6 A thermal adjustment range, 380/400 V AC coil, and IP55 protection.

What is a DOL starter used for?

A direct-on-line (DOL) starter connects a motor directly to the supply voltage at full line voltage, providing overload protection and switching control. It is the simplest motor starting method, used for small pumps, fans, compressors, and conveyors where high starting torque is acceptable.

What are the specifications of LG7K06Q706A29?

The LG7K06Q706A29 is an enclosed DOL starter rated for AC-3 duty with a thermal protection range of 1 to 1.6 A. It switches motors up to 0.55 kW at 400/415 V AC and 0.25 kW at 220/230 V AC. The control coil is 380/400 V AC 50/60 Hz. Enclosure is IP55 polycarbonate, 177x175x165 mm, with IK07 impact protection.

What is the difference between TeSys LG and TeSys GV?

The TeSys LG range is an enclosed DOL starter (contactor + circuit-breaker + controls in one box), while the TeSys GV range is a motor circuit breaker (manual motor starter) typically used upstream of a separate contactor. The LG integrates the start/stop and E-stop pushbuttons; the GV is a thermal-magnetic protection device without integrated controls.

MPN
LG7K06Q706A29