Skip to main content
Schneider Electric LG7K09Q7 — Motor Starters

Schneider TeSys LG7K09Q7 Enclosed DOL Starter, 9 A AC-3

MPNLG7K09Q7
Active

Schneider Electric TeSys LG enclosed DOL starter, 9 A AC-3, 380/400 V AC 50/60 Hz coil, IP55 polycarbonate enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG7K09Q7 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth177 mm

Product details

The Schneider Electric TeSys LG7K09Q7 is an enclosed direct-on-line (DOL) starter from the TeSys LG family, built for safety applications per IEC 60947-4-1 and IEC 60204-1. It ships as a polycarbonate enclosure with a contactor and push-button controls — start (white), stop (black), and a red mushroom-head emergency stop — but the circuit breaker is ordered separately. The 9 A AC-3 rating means it switches standard three-phase squirrel-cage motors under full load, not just resistive loads; at 380/400 V AC that covers motors roughly up to 4 kW, not 5.5 kW — the AC-3 current is the binding number for motor duty.

Enclosure, cable entry, and panel fit

It carries an IP55 rating (dust-protected and hose-down resistant) plus IK07 impact resistance, so it holds up in washdown or light industrial environments where a panel-mounted starter would need a separate enclosure. Cable entries are pre-cut: four Pg 13 and two Pg 16 knockouts on both top and bottom faces, giving flexibility for incoming mains and motor leads without drilling.

Coil voltage and control circuit

The control circuit is 380/400 V AC 50/60 Hz — a common line-voltage coil in European and Asian 400 V distribution. That means no separate control transformer is needed if the panel supply matches; the coil pulls directly from the mains phase-to-phase. The push-button station is integrated: white start, black stop, and a red mushroom-head emergency stop that latches mechanically.

Frequently asked questions

What circuit breaker should I use with the LG7K09Q7?

The LG7K09Q7 is an enclosed starter that requires a circuit breaker ordered separately. The TeSys LG range is designed to pair with Schneider GV2 or GV3 manual motor starters / circuit breakers; the specific frame size depends on the motor full-load current and short-circuit capacity required at the installation point.

What is the LG7K09Q7 cross reference or equivalent part number?

The LG7K09Q7 is a current-production Schneider TeSys LG enclosed DOL starter. Within the same TeSys LG range, the rating (9 A AC-3, 380/400 V coil) and enclosure size define the variant; there is no direct cross-reference from another manufacturer because the integrated push-button and emergency-stop layout is specific to this order code. For a parametric equivalent, match the 9 A AC-3 rating, 380/400 V coil, IP55 enclosure, and separate circuit-breaker requirement.

MPN
LG7K09Q7