Skip to main content
Schneider Electric LG7K09Q714 — Motor Starters

Schneider Electric LG7K09Q714 TeSys LG Enclosed DOL Starter,

MPNLG7K09Q714
Active

Schneider Electric TeSys LG LG7K09Q714 enclosed DOL starter, 4 kW at 400/415 V AC, AC-3, IP55, thermal protection 6–10 A, 380/400 V AC coil, polycarbonate enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG7K09Q714 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth177 mm

Product details

What this enclosed starter carries

The Schneider Electric LG7K09Q714 is a TeSys LG enclosed direct-on-line starter rated for 4 kW at 400/415 V AC (50/60 Hz) and 4 kW at 440 V AC, with a lower rating of 1.5 kW at 220/230 V AC. It's built for AC-3 motor switching — the standard category for squirrel-cage motors during starting and stopping — so the 4 kW figure is the motor load it handles, not a resistive current. Inside the polycarbonate box sits a contactor (LC1K) and a circuit-breaker (GV2ME) with thermal protection adjustable from 6 to 10 A. That adjustment range matches the motor full-load current for a 4 kW motor at 400 V — set it to the motor nameplate FLA, not the max. The control circuit runs on 380/400 V AC, so the coil voltage matches the line supply. No separate control transformer needed if the motor supply is 400 V three-phase.

IP55 and IK07 — what the enclosure buys you

IP55 means dust-protected and protected against water jets from any direction. That's good for washdown areas, outdoor installations under eaves, or anywhere a hose might hit the panel. IK07 impact resistance (2 J) handles accidental tool drops during maintenance — not armoured, but enough for a standard industrial floor. Cable entries: four knockouts top and bottom, two Pg 13 and two Pg 16 per side. That gives you room for the motor leads, control wires, and a spare.

Built-in safety and control

The front panel carries a white push-button for start, a black push-button for stop, and a red mushroom-head emergency stop. That covers the basic local control and emergency-off requirement per IEC 60204-1. The starter itself is listed to IEC 60947-4-1 (the standard for contactors and motor-starters) and IEC 60204-1 (safety of machinery).

This is a current-production part, so lead times are the usual factory cycle — no broker scavenger hunt needed.

Frequently asked questions

How do I get current pricing and availability for LG7K09Q714?

Current pricing and availability are confirmed at quote time against an RFQ through independent distribution.

What is LG7K09Q714's listed depth?

The listed depth is 177 mm.

What compliance documentation does this brand provide for LG7K09Q714?

The LG7K09Q714 is certified to IEC 60204-1 and IEC 60947-4-1. The polycarbonate enclosure carries IP55 and IK07 ratings per IEC 60529.

MPN
LG7K09Q714