Schneider Electric LP1D80004DW — Contactors

TeSys Deca LP1D80004DW 4-pole contactor, 96 V DC coil, 125 A

MPNLP1D80004DW
Active

Schneider Electric TeSys Deca LP1D80004DW, 4-pole contactor, 96 V DC wide-range coil, 125 A AC-1, 4 NO power poles.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LP1D80004DW — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LP1D80004DW — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Power circuit: <= 300 V DC
Utilisation categoryAC-1 AC-3 AC-3e AC-4

Contacts & Poles

LP1D80004DW — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LP1D80004DW — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude0...3000 m
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Approvals

LP1D80004DW — Approvals
ParameterValue
StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508

Mechanical

LP1D80004DW — Mechanical
ParameterValue
Width96 mm
Height127 mm
Depth181 mm

Product details

The Schneider Electric TeSys Deca LP1D80004DW is a 4-pole contactor with a 96 V DC wide-range coil, rated for utilisation categories AC-1, AC-3, AC-3e, and AC-4. The 4 NO power poles handle resistive loads (AC-1) and motor loads (AC-3/AC-3e/AC-4) up to the rated breaking and making capacity of 1100 A at 440 V per IEC 60947. Electrical durability is 0.8 Mcycles at 125 A AC-1, ≤440 V; mechanical durability is 4 Mcycles.

Approvals include CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508.

Integration notes

The power circuit uses a connector accepting 4–50 mm² flexible or solid cable; control circuit screw clamp terminals accept 1–4 mm². Tightening torque is 12 N·m for power connections and 1.2 N·m for control wiring. The coil draws 22 W inrush at 20 °C and has a time constant of 75 ms. Operating time is 6–20 ms opening, 20–35 ms closing. No built-in suppressor module — plan external diode or RC snubber for DC coil suppression.

Standards & environment

Fire resistance is 850 °C per IEC 60695-2-1; flame retardance is V1 per UL 94. The contactor withstands vibrations of 2 Gn (open) and 3 Gn (closed) at 5–300 Hz, and shocks of 8 Gn (open) and 10 Gn (closed) for 11 ms. Associated fuse rating for type 2 coordination on the power circuit is 200 A gG at ≤690 V. Maximum operating rate is 3600 cycles per hour at 60 °C.

Frequently asked questions

What compliance documentation does this brand provide?

The contactor is certified to CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508. The front face is IP20 rated per IEC 60529.

What are the key ratings of LP1D80004DW?

It is a 4-pole contactor with a 96 V DC coil, rated 125 A AC-1 (Ith), with breaking/making capacity of 1100 A at 440 V. Utilisation categories include AC-1, AC-3, AC-3e, and AC-4.

What is the depth of LP1D80004DW?

The depth is 181 mm.

MPN