Skip to main content
Schneider Electric LP2K06103BD — Contactors

TeSys K LP2K06103BD reversing contactor, 3P, 6 A AC-3, 24 VD

MPNLP2K06103BD
Obsolete

Schneider Electric TeSys K reversing contactor, LP2K06103BD, 3P, AC-3 ≤440 V 6 A, 1 NO, 24 V DC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K06103BD — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LP2K06103BD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LP2K06103BD — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K06103BD — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K06103BD — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It carries a 3-pole power circuit rated for AC-3 duty at 6 A up to 440 V, with a 24 V DC coil. The AC-3 rating means it switches motor loads under full running current — the standard category for squirrel-cage induction motors during starting and stopping.

The 6 A AC-3 rating at 440 V defines the motor current it can handle. The 24 V DC coil is common in control panels with a DC supply rail; verify your control voltage matches before wiring.

Deployment context

As a reversing contactor, this part mounts in a control panel to switch a motor between forward and reverse rotation — common on conveyor drives, hoists, and small pump sets where direction reversal is needed. The preassembled reversing busbar simplifies wiring by mechanically interlocking the two contactors so both cannot close simultaneously, preventing a phase-to-phase short. The 90 mm width and 58 mm height fit a standard DIN-rail footprint alongside other TeSys K control gear.

Frequently asked questions

What replaces the LP2K06103BD?

There is no official direct replacement listed. For a legacy panel, the best approach is to source the exact part through the surplus channel or evaluate a full contactor replacement from the current TeSys range, which will require verifying mounting dimensions, coil voltage, and auxiliary contact configuration.

What are the key ratings for fit verification?

AC-3 motor switching current: 6 A at ≤440 V. Coil: 24 V DC. Poles: 3 NO power. IP20 enclosure protection. Operating temperature: -25 to 50 °C.

What compliance documentation is available?

The part carries V1 flame retardance per UL 94, IP20 per VDE 0106, and protective treatment per IEC 60068 and DIN 50016. Specific RoHS/REACH declarations should be verified against the manufacturer's documentation for this obsolete code.

MPN
LP2K06103BD