Skip to main content
Schneider Electric LUCA1XFUTQ

Schneider Electric LUCA1XFUTQ TeSys U Control Unit, 0.25 kW

MPN LUCA1XFUTQ
Obsolete

Schneider Electric TeSys U standard control unit, LUCA1XFUTQ, 0.25 kW at 400-440 V AC, 110-240 V AC/DC control voltage, plug-in front face.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCA1XFUTQ specifications
ParameterValue
Load type3-phase motor - cooling: self-cooled
Main product or component typeStandard control unit
Voltage690 V AC
Coil voltage110...220 V DC 110...240 V AC
Insulation voltage ui690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Utilization categoryAC-41 AC-44 AC-43
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating time35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 50 ms closing with LUB12 for control circuit 50 ms closing with LUB32 for control circuit 50 ms closing with LUB38 for control circuit
Operating temperature-25...70 °C

Product details

The LUCA1XFUTQ is a standard control unit in the TeSys U line — the brains of a modular motor starter that handles overload, short-circuit, and phase-failure protection for a 3-phase motor. At 0.25 kW rated for 400...440 V AC 50/60 Hz, it's sized for small pumps, fans, or conveyors where you want coordinated motor protection in one package.

Control voltage is 110...240 V AC or 110...220 V DC — common panel supplies, but note the DC range tops out at 220 V, not 240 V. The unit pulls 280 mA maximum while closing and drops to 35 mA sealed (AC) or 25 mA (DC with certain power bases), so the control transformer or DC supply needs headroom for that inrush. Tripping threshold is 14.2 x Ir +/- 20 %, meaning it clears a bolted fault fast — the Class 10 overload curve (per IEC 60947-6-2 and UL 508) gives you 10 seconds at 600% of the thermal setting, standard for standard-duty motor starts. IP20 on the front panel and wired terminals keeps fingers out; IP40 on the front face outside the connection zone is fine for a clean enclosure but not washdown.

MPN