Schneider Electric LV838883 — Air Circuit Breakers

Schneider Electric LV838883 MasterPact MTZ2, 1200 A, 3P, Dra

MPNLV838883
Active

Schneider Electric MasterPact MTZ2, LV838883, 3-pole drawout circuit breaker, 1200 A rated, L breaking capacity, 600 VAC, UL 489, without Micrologic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV838883 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV838883 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV838883 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)30 kA 0.5 s UL 489
Breaking capacity codeL
LV838883 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
LV838883 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV838883 is a MasterPact MTZ2 drawout circuit breaker from Schneider Electric, rated 1200 A at 104 °F (40 °C) with L breaking capacity (200 kA Icu at 240 V AC, 150 kA at 480 V AC, 100 kA at 600 V AC per UL 489). It is a 3-pole unit without a Micrologic trip unit, intended for protection applications on 50/60 Hz AC networks up to 600 VAC.

Schneider Electric has marked the LV838883 as obsolete.

Breaking Capacity & Selectivity Planning

The L breaking capacity code delivers 200 kA Icu at 240 V AC, 150 kA at 480 V AC, and 100 kA at 600 V AC — all UL 489. That puts this breaker in the high-interrupting tier for large commercial or industrial switchboards. The 30 kA Icw (short-time withstand for 0.5 s per UL 489) supports selective coordination downstream, letting you hold the main closed while a feeder clears a fault.

Drawout Mount & Panel Integration

Drawout mounting means the breaker chassis stays wired to the bus, and the removable cradle slides in and out for maintenance or replacement without disturbing the power connections. The unit measures 17.5 in wide by 17.3 in tall by 16.8 in deep — a standard switchgear cubicle footprint. Base-plate rails support the drawout mechanism; the 4.5 in connection pitch matches typical bus-bar spacing.

Trip Unit & Protection

This listing ships without a Micrologic trip unit — the buyer sources the trip unit separately to match the protection curve (LSIG, LSI, or electronic-only) needed for the downstream load. Integral instantaneous protection is set at 72–88 kA. Maximum breaking time is 9 ms; maximum closing response time is 70 ms.

Frequently asked questions

What is the closest alternative to LV838883 in the MasterPact family?

No official successor order code is recorded for this MPN. A direct replacement would require cross-referencing the same frame size (MTZ2), rated current (1200 A), pole count (3P), drawout mount, and L breaking capacity — then selecting the current-generation MasterPact MTZ2 catalog number with the same parameters and a Micrologic trip unit if needed.

What is LV838883's listed depth?

The depth is 16.8 in (426.8 mm).

What is LV838883's listed width?

The width is 17.5 in (444.3 mm).