Skip to main content
Schneider Electric LV838885 — Air Circuit Breakers

Schneider LV838885 MasterPact MTZ2 1600A 3P Drawout, Obsolet

MPNLV838885
Active

Schneider Electric MasterPact MTZ2, LV838885, 1600A, 3-pole, drawout, L breaking capacity, 600VAC, UL 489, without Micrologic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV838885 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV838885 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV838885 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)30 kA 0.5 s UL 489
Breaking capacity codeL
LV838885 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
LV838885 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV838885 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, rated 1600 A at 104 °F (40 °C), 3-pole, with L breaking capacity code. It's listed for 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC under UL 489. The unit ships without a Micrologic trip unit, so you'll need to order that separately.

The interrupting ratings (200 kA Icu at 240 V, 150 kA at 480 V, 100 kA at 600 V) tell you the maximum fault current the breaker can safely clear at those voltages; match these to your available fault current at the service entrance. The 30 kA short-time withstand current (Icw) for 0.5 s per UL 489 means the breaker can hold in during a delayed trip coordination scheme, which is key for selective coordination in a distribution panel.

Frequently asked questions

What is the breaking capacity code L mean?

The L breaking capacity code on this MasterPact MTZ2 indicates a standard interrupting rating level, as opposed to H (high) or S (superior) codes in the same family.

Does LV838885 come with a trip unit?

No, the LV838885 ships without a Micrologic trip unit. You must order the trip unit separately to match your protection curve needs.