Schneider Electric LV838917 — Air Circuit Breakers

Schneider LV838917 MasterPact MTZ2 800A 3P Drawout, 200 kA I

MPNLV838917
Active

Schneider Electric MasterPact MTZ2 series, LV838917, 3-pole drawout circuit breaker, 800 A rated, LF breaking capacity, 600 VAC UL 489.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV838917 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV838917 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV838917 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)22 kA 0.5 s UL 489
Breaking capacity codeLF
LV838917 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
LV838917 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV838917 is a MasterPact MTZ2 drawout circuit breaker — 3-pole, 800 A continuous rating at 40 °C, built for UL 489 applications up to 600 VAC. The LF breaking capacity code delivers 200 kA Icu at 240 VAC, 150 kA Icu at 480 VAC, and 100 kA Icu at 600 VAC. That spread covers most low-voltage distribution main and feeder roles in North American industrial switchgear. Drawout mounting means the breaker slides into a cassette — you can rack it out for maintenance or swap without disturbing the bus connections. The base plate rails and 4.5 in (115 mm) connection pitch match the standard MTZ2 switchgear lineup. Panel builders will recognize the footprint: 17.5 in wide × 17.3 in tall × 16.8 in deep.

At 480 VAC it still holds 150 kA Icu, and at 600 VAC it delivers 100 kA Icu. The short-time withstand (Icw) is 22 kA for 0.5 s under UL 489. That matters for selective coordination: downstream breakers can clear a fault while this breaker holds closed, keeping the rest of the bus live. The integral instantaneous protection trips between 49.5 and 55.5 kA, so it will not nuisance-trip on a moderate overload but clears hard faults fast. Maximum breaking time is 9 ms, closing response 70 ms — fast enough to limit arc-flash energy in most installations. The 800 A CT rating matches the continuous current rating; no need to re-spec the trip unit if you are replacing like-for-like.

Frequently asked questions

What replaces the LV838917 in the MasterPact MTZ2 family?

There is no single official successor order code published for this specific LF breaking-capacity variant. Within the MTZ2 platform, the same 800 A 3-pole drawout frame accepts different trip units and breaking capacity ratings — a current-production electronic-trip version can often drop into the existing cassette. Verify the required Icu level and trip unit before ordering a replacement.

What are the key UL 489 ratings for LV838917?

200 kA Icu at 240 VAC, 150 kA Icu at 480 VAC, and 100 kA Icu at 600 VAC. Short-time withstand (Icw) is 22 kA for 0.5 s. Integral instantaneous protection range is 49.5 to 55.5 kA.

Where can I buy LV838917 and how is it quoted?

We source the LV838917 through independent distribution channels — new-surplus and verified inventory. Submit an RFQ for your target quantity; availability and current pricing are confirmed at quote time. No stock figures or lead-time numbers are published for obsolete parts.