Schneider LV838919 MasterPact MTZ2 Circuit Breaker, 1200 A,

MPNLV838919
Active

Schneider Electric MasterPact MTZ2, LV838919, 3-pole drawout circuit breaker, 1200 A rated, LF breaking capacity, 600 VAC, UL 489.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV838919 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV838919 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV838919 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)22 kA 0.5 s UL 489
Breaking capacity codeLF
LV838919 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
LV838919 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The Schneider Electric LV838919 is a MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 1200 A at 40 °C, with LF breaking capacity. It's a UL 489 listed device for 600 VAC service, designed for main or feeder protection in switchgear where drawout extraction simplifies maintenance and downstream isolation. Its interrupting ratings are substantial: 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC — all per UL 489.

If you're managing a lifecycle transition, the MasterPact MTZ2 series has been succeeded by the MasterPact MTZ3 family. The exact replacement order code depends on the required breaking capacity and accessory configuration; a cross-reference from the original switchgear one-line or panel schedule is the cleanest way to confirm fit.

The drawout cradle (mounting mode) means the breaker slides out for inspection or replacement without disturbing the bus connections, which is standard for main breakers in double-ended or tie-configuration gear. The LF breaking capacity code indicates the higher interrupting tier within the MTZ2 family. With a 50 kA rated breaking and making capacity and a 22 kA short-time withstand (Icw) for 0.5 s per UL 489, this breaker can handle delayed-tripping coordination schemes where downstream devices clear faster while the main holds in for a set duration. Integral instantaneous protection is set at 49.5 to 55.5 kA — that's the magnetic trip threshold for bolted faults. The maximum breaking time is 9 ms, and closing response is 70 ms, which are typical for this class of power breaker.

Mounting is drawout on base plate rails, with a connection pitch of 115 mm (4.5 in) between phases. Overall dimensions: 17.5 in wide, 17.3 in high, 16.8 in deep. That's a substantial footprint — verify the switchgear cell opening and racking mechanism compatibility before specifying, especially if retrofitting into an existing lineup.

Frequently asked questions

Where can I buy LV838919 and get a price?

We source this part to order through independent distribution. Submit an RFQ — availability and current pricing are confirmed at quote time. No stock or price figures are published here because the supply position changes.

What is the closest alternative to LV838919 in the MasterPact family?

The direct successor series is MasterPact MTZ3. The exact replacement order code depends on the required breaking capacity (LF tier) and accessory set. A cross-reference from the original switchgear documentation is the most reliable way to identify the correct MTZ3 variant.

What are the interrupting ratings for LV838919?

Per UL 489: 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC. The rated short-time withstand current (Icw) is 22 kA for 0.5 s.