Skip to main content
Schneider Electric LV839000 — Air Circuit Breakers

LV839000 Masterpact MTZ3 40 HA Switch Disconnector, 4000 A

MPNLV839000
Active

Schneider Electric Masterpact MTZ3 40 HA, LV839000, non-automatic switch disconnector, 4000 A, 4-pole drawout, 65 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV839000 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution
LV839000 — Electrical ratings
ParameterValue
Rated operational current (Ie)4000 A 104 °F (40 °C)
Poles4P
Network typeAC
Network frequency50/60 Hz
LV839000 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 0.5 s ANSI C37.50
Breaking capacity65.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 65.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 65.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
LV839000 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width40.5 in (1028.7 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839000 is a non-automatic switch disconnector from the Masterpact MTZ3 series, designated 40 HA. It is a 4-pole drawout unit rated 4000 A continuous at 40 °C, built for distribution-level switching and isolation in ANSI-based power systems. The 65 kA Icu breaking capacity at 254 V, 508 V, and 635 V AC 50/60 Hz (with external relay per ANSI C37.50) means it can safely interrupt fault currents up to that level across the common low-voltage distribution voltages — the same rating at three voltage points, not a derated curve. The short-time withstand current is 85 kA for 0.5 s per ANSI C37.50, which governs coordination with downstream breakers during a fault-ride-through event.

Drawout mounting on a chassis support — the unit withdraws from its cradle for safe isolation during maintenance without unbolting power cables. The 4-pole configuration covers three-phase plus neutral switching, standard for distribution switchboards. Physical footprint: 40.5 in wide by 18.8 in high by 16.8 in deep. Connection pitch is 9.06 in, which sets the bus-bar spacing in the switchgear lineup. Control is via push-button on the front fascia.

Frequently asked questions

What is the breaking capacity of LV839000?

The LV839000 has a 65 kA Icu breaking capacity at 254 V, 508 V, and 635 V AC 50/60 Hz with external relay per ANSI C37.50. The short-time withstand current is 85 kA for 0.5 s per ANSI C37.50.

Where can I buy LV839000 and how is it quoted?

The LV839000 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
LV839000