Skip to main content
Schneider Electric LV839005 — Air Circuit Breakers

LV839005 Masterpact MTZ3 60 HA Switch Disconnector, 6000 A,

MPNLV839005
Active

Schneider Electric Masterpact MTZ3 60 HA, LV839005, non-automatic switch disconnector, 6000 A rated operational current, 65 kA Icu at 635 V AC, 3-pole, fixed mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV839005 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution
LV839005 — Electrical ratings
ParameterValue
Rated operational current (Ie)6000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839005 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 0.5 s ANSI C37.50
Breaking capacity65.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 65.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 65.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
LV839005 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Connection pitch9.06 in (230 mm)
LV839005 — Other specifications
ParameterValue
Device short nameMTZ3 60 HA

Product details

The LV839005 is a Schneider Electric Masterpact MTZ3 60 HA non-automatic switch disconnector rated for 6000 A continuous at 104 °F (40 °C). It carries a 65 kA interrupting capacity at 635 V AC (ANSI C37.50) when used with an external relay, and a short-time withstand of 85 kA for 0.5 s. That 65 kA rating holds at 254 V, 508 V, and 635 V — meaning it clears faults across the common low-voltage distribution levels without derating.

This is a 3-pole fixed-mount switch disconnector built for distribution duty. The 85 kA short-time withstand (0.5 s) tells you the device can ride through a fault long enough for an upstream breaker to clear, which is critical for selective coordination studies.

Physical footprint

Fixed-mount chassis: 30.2 in wide, 13.9 in tall, 11.7 in deep. Connection pitch is 9.06 in. That footprint matches standard ANSI switchboard cubicle layouts — verify the door cutout and bus spacing against your existing gear before ordering.

Frequently asked questions

What is the breaking capacity of LV839005?

65 kA Icu at 254 V, 508 V, and 635 V AC 50/60 Hz per ANSI C37.50, with an external relay. Short-time withstand is 85 kA for 0.5 s.

Where can I buy LV839005 and get current pricing?

LV839005 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.