Schneider LV839029 MasterPact MTZ3 4000A 4P Drawout, 100 kA

MPN LV839029
Active

Schneider Electric MasterPact MTZ3, LV839029, 4000 A rated, 4-pole drawout, H3 breaking capacity 100 kA Icu at 508 V AC ANSI C37.50, without Micrologic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839029 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width40.5 in (1028.7 mm)
Height18.8 in (478.1 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection

Product details

The LV839029 is a MasterPact MTZ3 frame drawout circuit breaker rated 4000 A continuous at 104 °F (40 °C) — that is the full-frame current, not a derated number, so it carries the main bus without a bump. The H3 breaking capacity delivers 100 kA Icu at 508 V AC per ANSI C37.50, meaning it safely interrupts a fault up to that level and recloses without service. For a 635 V AC system the Icu drops to 85 kA, still enough for most industrial secondary-distribution switchgear. The short-time withstand (Icw) is 85 kA for 0.5 s, which is the figure you use for selective coordination with downstream feeders — if your upstream breaker clears in under half a cycle, this frame holds closed and lets the downstream device isolate the fault. Integral instantaneous protection trips between 171 kA and 209 kA — that is the magnetic-only floor, not the adjustable pickup. The 25–30 ms maximum break time and 70 ms maximum closing response time are the mechanism's native speed; they govern arc-flash incident energy calculations for the IEEE 1584 study. Mechanical durability is 12,500 cycles, electrical durability 2,800 cycles per ANSI C37.50 — both are the mechanism's life before major overhaul, not the trip-unit life.

Drawout mounting and panel fit

This is a drawout chassis — the breaker cassette slides into a fixed cradle, so you can rack it out for maintenance without unbolting bus bars. The mounting support is base plate rails; the connection pitch is 9.06 in (230 mm) between phase centers, which is the standard MasterPact MTZ footprint. Panel cutout dimensions: width 40.5 in (1028.7 mm), height 18.8 in (478.1 mm), depth 16.8 in (426.8 mm). No Micrologic trip unit is included — you order the trip unit separately to match your protection curve (LSIG, LSI, or G).