Schneider Electric LV839032 MasterPact MTZ3 5000A 4P Circuit

MPNLV839032
Active

Schneider Electric MasterPact MTZ3, LV839032, circuit breaker, 5000 A rated, 4-pole, fixed mount, H3 breaking capacity, 635 VAC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839032 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839032 — Electrical ratings
ParameterValue
Poles4P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839032 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839032 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839032 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate Rails
Width39.2 in (996.3 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Neutral pole positionLeft
Connection pitch9.06 in (230 mm)

Product details

The LV839032 is a MasterPact MTZ3 air circuit breaker rated 5000 A at 104 °F (40 °C) ambient, 4-pole, fixed-mount, with an H3 breaking capacity code. The H3 rating delivers 100 kA Icu at 508 V AC and 85 kA Icu at 635 V AC per ANSI C37.50 — meaning it can safely interrupt fault currents up to those levels at the respective voltages, which is the figure that governs main-breaker coordination studies. The 85 kA Icw short-time withstand current for 0.5 s (ANSI C37.50) tells you it holds through delayed tripping sequences for selective coordination downstream. This breaker ships without a Micrologic trip unit, so the trip curve is set by the unit you install separately.

Deployment context

Fixed-mount base-plate installation on rails — the 39.2 in (996.3 mm) width and 13.9 in (352.2 mm) height define the panel cutout and bus-bar takeoff spacing. Neutral is on the left; connection pitch is 9.06 in (230 mm). The 11.7 in (297.7 mm) depth fits standard switchgear cubicle depths, but verify gland-plate clearance for the rear bus connections. At 5000 A continuous, bus-bar sizing and ventilation are the limiting factors, not the breaker footprint.

Frequently asked questions

How do I get current pricing and availability for LV839032?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is LV839032's breaking capacity at 508 V AC?

The H3 breaking capacity code delivers 100 kA Icu at 508 V AC per ANSI C37.50.