LV839034 MasterPact MTZ3 6000A 3P Fixed Circuit Breaker, H3

MPNLV839034
Active

Schneider Electric MasterPact MTZ3, LV839034, 3-pole fixed circuit breaker, 6000 A rated, H3 breaking capacity, 635 VAC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839034 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839034 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839034 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839034 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839034 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate Rails
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839034 is a MasterPact MTZ3 frame — a 3-pole, fixed-mount air circuit breaker rated 6000 A continuous at 40 °C, built to ANSI C37.50. It ships as a single unit (one per package) without a Micrologic trip unit. The kit includes the breaker frame, the fixed base plate with rails, and the push-button control interface. No trip unit, no plug-in accessories — those are separate line items. If you are kitting a replacement for a line-down situation, verify the trip unit order code alongside this frame to avoid a second trip.

Breaking capacity — what the H3 code delivers

The H3 breaking capacity code means this breaker can interrupt 100 kA Icu at 254 V AC, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC (all per ANSI C37.50). The rated short-time withstand current (Icw) is 85 kA for 0.5 s — that is the fault current the frame can carry without damage during a delayed trip coordination scheme. The integral instantaneous protection triggers between 171 kA and 209 kA, covering the high-end fault range. Maximum break time is 25 to 30 ms; closing response is 70 ms max.

Physical fit — panel and enclosure integration

Fixed-mount on a base plate with rails. Dimensions: width 30.2 in (767 mm), height 13.9 in (352.2 mm), depth 11.7 in (297.7 mm). Connection pitch is 9.06 in (230 mm) between phases. The breaker is designed for ANSI-style switchgear lineups — the fixed version bolts directly to the bus, not a draw-out cassette. For a panel OEM or MRO planner, the depth is the critical dimension for enclosure depth: 297.7 mm means a standard 400 mm deep enclosure leaves clearance for rear connections and cable bending radius.

Frequently asked questions

Where can I buy LV839034?

The LV839034 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of LV839034?

Rated 6000 A continuous at 40 °C, 3 poles, H3 breaking capacity (100 kA Icu at 254 V AC, 100 kA at 508 V AC, 85 kA at 635 V AC), Icw 85 kA for 0.5 s, integral instant protection 171-209 kA.

What is the physical size of LV839034?

Width 30.2 in (767 mm), height 13.9 in (352.2 mm), depth 11.7 in (297.7 mm). Connection pitch 9.06 in (230 mm).

Does LV839034 include a trip unit?

No, the LV839034 ships without a Micrologic trip unit. The trip unit must be ordered separately.