Skip to main content
Schneider Electric LV839034

LV839034 MasterPact MTZ3 6000A 3P Fixed Circuit Breaker, H3

MPN LV839034
Active

Schneider Electric MasterPact MTZ3, LV839034, 3-pole fixed circuit breaker, 6000 A rated, H3 breaking capacity, 635 VAC, without Micrologic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839034 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth11.7 in (297.7 mm)
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection

Product details

The LV839034 is a MasterPact MTZ3 frame — a 3-pole, fixed-mount air circuit breaker rated 6000 A continuous at 40 °C, built to ANSI C37.50. It ships as a single unit (one per package) without a Micrologic trip unit. The kit includes the breaker frame, the fixed base plate with rails, and the push-button control interface. No trip unit, no plug-in accessories — those are separate line items. If you are kitting a replacement for a line-down situation, verify the trip unit order code alongside this frame to avoid a second trip.

Breaking capacity — what the H3 code delivers

The H3 breaking capacity code means this breaker can interrupt 100 kA Icu at 254 V AC, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC (all per ANSI C37.50). The rated short-time withstand current (Icw) is 85 kA for 0.5 s — that is the fault current the frame can carry without damage during a delayed trip coordination scheme. The integral instantaneous protection triggers between 171 kA and 209 kA, covering the high-end fault range. Maximum break time is 25 to 30 ms; closing response is 70 ms max.

Physical fit — panel and enclosure integration

Fixed-mount on a base plate with rails. Dimensions: width 30.2 in (767 mm), height 13.9 in (352.2 mm), depth 11.7 in (297.7 mm). Connection pitch is 9.06 in (230 mm) between phases. The breaker is designed for ANSI-style switchgear lineups — the fixed version bolts directly to the bus, not a draw-out cassette. For a panel OEM or MRO planner, the depth is the critical dimension for enclosure depth: 297.7 mm means a standard 400 mm deep enclosure leaves clearance for rear connections and cable bending radius.

MPN
LV839034