Schneider Electric LV839035 — Air Circuit Breakers

Schneider LV839035 MasterPact MTZ3 6000A 3P Drawout Breaker,

MPNLV839035
Active

Schneider Electric MasterPact MTZ3, LV839035, 3-pole drawout circuit breaker, 6000 A rated, H3 breaking capacity, 635 VAC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839035 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839035 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839035 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839035 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839035 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric LV839035 is a MasterPact MTZ3 drawout circuit breaker rated for 6000 A continuous at 104 °F (40 °C), 3-pole, with H3 breaking capacity. It carries 100 kA Icu at 254 V and 508 V AC, and 85 kA Icu at 635 V AC per ANSI C37.50 — meaning it can safely interrupt fault currents up to those levels without cascading upstream. The breaker ships without a Micrologic trip unit, so the buyer selects and installs the protection relay separately, matching the trip curve to the downstream load.

Breaking performance and coordination

The H3 breaking capacity code delivers 170 kA rated breaking and making capacity and an integral instantaneous protection range of 171–209 kA. Short-time withstand current (Icw) is 85 kA for 0.5 s per ANSI C37.50, which governs how long the breaker can carry a fault while downstream devices clear — critical for selective coordination in a distribution panel. Maximum breaking time is 25–30 ms; closing response is 70 ms.

Physical integration and mounting

Drawout mount on base plate rails — the breaker slides into a fixed cradle, allowing removal without disconnecting power cables. Overall dimensions: width 31.07 in (789.1 mm), height 18.8 in (478.1 mm), depth 16.8 in (426.8 mm). Connection pitch is 9.06 in (230 mm). Panel builders should verify the cradle cutout and bus bar spacing against these dimensions before committing the switchgear layout.

Mechanical durability is 12,500 cycles per ANSI C37.50; electrical durability is 2,800 cycles — the electrical figure is the limiting factor for applications with frequent switching, such as capacitor bank or motor feeder duty.

Frequently asked questions

What is the breaking capacity of LV839035?

H3 breaking capacity delivers 100 kA Icu at 254 V and 508 V AC, and 85 kA Icu at 635 V AC per ANSI C37.50. Rated breaking and making capacity is 170 kA.

Does LV839035 include a trip unit?

No, the LV839035 ships without a Micrologic trip unit. The buyer selects and installs the protection relay separately to match the trip curve to the load.

What are the mounting dimensions of LV839035?

Width 31.07 in (789.1 mm), height 18.8 in (478.1 mm), depth 16.8 in (426.8 mm). Connection pitch is 9.06 in (230 mm). Drawout mount on base plate rails.

Where can I buy LV839035 and how is it quoted?

The LV839035 is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ.

MPN