Schneider Electric LV839036 — Air Circuit Breakers

Schneider Electric LV839036 MasterPact MTZ3 6000A 4P Circuit

MPNLV839036
Active

Schneider Electric MasterPact MTZ3, ANSI circuit breaker, LV839036, 6000 A rated, 4-pole, fixed mount, H3 breaking capacity, 635 VAC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839036 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839036 — Electrical ratings
ParameterValue
Poles4P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839036 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839036 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839036 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate Rails
Width39.2 in (996.3 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Neutral pole positionLeft
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric LV839036 is a MasterPact MTZ3 ANSI power circuit breaker rated for 6000 A continuous at 40 °C, 4-pole, fixed-mount, with an H3 breaking capacity class. The H3 rating delivers 100 kA Icu at 508 V AC and 85 kA Icu at 635 V AC per ANSI C37.50 — that is the maximum fault current it can safely interrupt without damage, so it is sized for high-fault-capacity main service entrances or large feeder positions where upstream fault current can exceed 85 kA. The short-time withstand rating of 85 kA for 0.5 s (Icw) means it can carry that fault current for half a second while a downstream device clears, which is the coordination window a selective system needs. The unit ships without a Micrologic trip unit — the buyer selects and installs the appropriate electronic trip module separately, matching the protection curve (LSIG, LS, or others) to the load. This is standard for the MTZ platform: the breaker frame and the trip system are ordered as separate line items.

Deployment context

Fixed-mount base plate with rails — the breaker bolts into a switchgear lineup or a dedicated enclosure. At 39.2 in wide by 13.9 in tall by 11.7 in deep, it occupies a standard vertical section in an ANSI metal-enclosed low-voltage switchgear assembly.

Frequently asked questions

How do I get current pricing and availability for LV839036?

Submit an RFQ through the storefront. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

What are the key ratings of the LV839036?

6000 A continuous rated current at 40 °C, 4-pole, H3 breaking capacity (100 kA Icu at 508 V AC, 85 kA at 635 V AC per ANSI C37.50), short-time withstand 85 kA for 0.5 s, fixed-mount base plate.

What compliance documentation does this brand provide for LV839036?

Schneider Electric provides UL and ANSI compliance documentation for the MasterPact MTZ3 series. The H3 breaking capacity is certified per ANSI C37.50. Specific UL file numbers and RoHS/REACH declarations are available on request at quote time.