Schneider Electric LV839037 — Air Circuit Breakers

LV839037 MasterPact MTZ3 6000A 4P Drawout Circuit Breaker, H

MPNLV839037
Active

Schneider Electric MasterPact MTZ3, LV839037, 4-pole drawout circuit breaker, 6000 A rated, H3 breaking capacity 100 kA Icu at 508 V AC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839037 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839037 — Electrical ratings
ParameterValue
Poles4P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839037 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839037 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839037 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width40.5 in (1028.7 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Neutral pole positionLeft
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric MasterPact MTZ3 LV839037 is a 4-pole drawout air circuit breaker rated for 6000 A continuous at 104 °F (40 °C), with an H3 breaking capacity code that delivers 100 kA Icu at 508 V AC and 85 kA Icu at 635 V AC per ANSI C37.50. It ships without a Micrologic trip unit, so you spec and install the protection relay separately — common practice on large-frame drawout breakers where the trip unit is ordered to match the coordination study.

The 6000 A frame at 40 °C ambient is the line-rated current; above that temperature you derate per the manufacturer's curve. The H3 breaking capacity means this breaker can safely interrupt 100 kA symmetrical at 508 V AC and 85 kA at 635 V AC — that's a high-fault installation, typically a main or large feeder breaker in an industrial switchgear lineup. The short-time withstand (Icw) is 85 kA for 0.5 s, which tells you it holds in on a delayed trip long enough for downstream breakers to clear a fault. Mechanical endurance is 12,500 cycles and electrical endurance 2,800 cycles per ANSI C37.50 — the electrical figure governs for a main breaker that sees infrequent fault interruption, while the mechanical count matters if you're using it for regular load switching.

Drawout mounting means the breaker chassis stays bolted to the switchgear while the removable cradle slides in and out — essential for maintenance and arc-flash safety because you can rack it to the test or disconnected position without pulling cables. The base-plate rails and 230 mm connection pitch are sized for standard ANSI metal-clad switchgear compartments. Neutral sits on the left; overall footprint is 40.5 in wide by 18.8 in tall by 16.8 in deep.

Frequently asked questions

Where can I buy LV839037 and how do I get a price?

We source LV839037 to order against an RFQ. Submit a quote request; availability and current pricing are confirmed at quote time.

What is the breaking capacity of LV839037?

The H3 breaking capacity delivers 100 kA Icu at 254 V AC, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC per ANSI C37.50.

What are the physical dimensions of LV839037?

Width 40.5 in (1028.7 mm), height 18.8 in (478.1 mm), depth 16.8 in (426.8 mm). Drawout mounting with a 230 mm connection pitch.