Skip to main content
Schneider Electric LV839057 — Air Circuit Breakers

Schneider Electric LV839057 Masterpact MTZ3 40 HF, 4000A, 3P

MPNLV839057
Active

Schneider Electric Masterpact MTZ3 40 HF, LV839057, switch disconnector, 4000 A, ANSI, 3P, drawout.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839057 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839057 — Electrical ratings
ParameterValue
Rated operational current (Ie)4000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839057 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 1.5 s ANSI C37.50
Breaking capacity100.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 100.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 85.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50

Mechanical & connection

LV839057 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839057 is a Masterpact MTZ3 40 HF switch disconnector rated for 4000 A at 104 °F (40 °C) — that's the continuous current it carries without derating in a typical 40 °C ambient panel. The 100 kA Icu at 254 V AC (and 508 V AC, with 85 kA at 635 V AC) tells you the maximum fault current it can safely interrupt once, per ANSI C37.50. That 100 kA figure governs your upstream fault-duty coordination: if your service entrance or switchgear bus can deliver 100 kA symmetrical at 254 V, this breaker holds the line without cascading. The 85 kA Icw for 1.5 seconds (ANSI C37.50) is the short-time withstand — it lets the breaker ride through a delayed trip coordination window, holding closed while downstream devices clear a fault. That matters for selective coordination in a distribution panel: you can set the trip delay long enough to let a feeder breaker clear first, without the main tripping.

Drawout chassis integration

Drawout mounting means the breaker mechanism slides out of its chassis for maintenance or swap without disturbing the line and load connections. The chassis mounts on a support frame, with a connection pitch of 9.06 in (230 mm) between phases. Overall footprint: 31.07 in wide × 18.8 in high × 16.8 in deep (789 × 478 × 427 mm). That depth includes the drawout travel — verify your enclosure depth allows full rack-out clearance before committing the panel layout.

Frequently asked questions

What is the breaking capacity of LV839057?

100 kA Icu at 254 V AC 50/60 Hz, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC, all per ANSI C37.50 with external relay. The short-time withstand (Icw) is 85 kA for 1.5 s.

Where can I buy LV839057 and how is it quoted?

The LV839057 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the depth of LV839057?

The listed depth is 16.8 in (426.8 mm), which includes the drawout mechanism travel. Verify enclosure depth allows full rack-out clearance.

MPN
LV839057