Schneider Electric LV839061 — Air Circuit Breakers

Schneider Electric LV839061 Masterpact MTZ3 50 HF Switch Dis

MPNLV839061
Active

Schneider Electric Masterpact MTZ3 50 HF, switch disconnector, LV839061, 5000 A, 3P, drawout, 100 kA Icu at 508 V AC.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839061 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839061 — Electrical ratings
ParameterValue
Rated operational current (Ie)5000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839061 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 1.5 s ANSI C37.50
Breaking capacity100.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 100.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 85.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50

Mechanical & connection

LV839061 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric LV839061 is a Masterpact MTZ3 50 HF automatic switch disconnector rated for 5000 A at 104 °F (40 °C) — that is the continuous current it carries without derating in a standard 40 °C ambient. Breaking capacity hits 100 kA Icu at 508 V AC 50/60 Hz with an external relay per ANSI C37.50, and 85 kA Icu at 635 V AC. Rated short-time withstand current [Icw] is 85 kA for 1.5 s per ANSI C37.50, so it holds through delayed-tripping coordination windows without the contacts welding shut.

Lifecycle and sourcing — active, available to order

This is not a phase-out or NRND part — it is current-catalog, so you can spec it into a new switchboard lineup without worrying about a last-time-buy window closing.

Integration — what fits around it

Chassis-mount, drawout, 3-pole. The connection pitch is 9.06 in (230 mm) between phases — verify bus-bar drilling matches before the switchboard steel is punched. Overall footprint: 31.07 in wide × 18.8 in high × 16.8 in deep (789.1 × 478.1 × 426.8 mm). That depth includes the drawout cradle; account for rear cable egress and the external relay mounting space. Push-button control on the front fascia for local open/close; AC control voltage network type.

Frequently asked questions

What is the breaking capacity of LV839061 at 508 V?

100 kA Icu at 508 V AC 50/60 Hz with an external relay, per ANSI C37.50. At 635 V AC it is 85 kA Icu.

Where can I buy LV839061 and what is the lead time?

Sourced to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no standard lead time published for this active catalog item.

What is the rated continuous current of LV839061?

5000 A at 104 °F (40 °C) ambient — that is the [Ie] rated operational current for this switch disconnector.

MPN