Skip to main content
Schneider Electric LV839064 — Air Circuit Breakers

Schneider LV839064 Masterpact MTZ3 60 HF Switch Disconnector

MPNLV839064
Active

Schneider Electric Masterpact MTZ3 60 HF, LV839064, switch disconnector, 6000 A, ANSI, 3P, fixed.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839064 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839064 — Electrical ratings
ParameterValue
Rated operational current (Ie)6000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839064 — Breaking & withstand capacity
ParameterValue
Breaking capacity100.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 100.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 85.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50

Mechanical & connection

LV839064 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.1 mm)
Connection pitch9.06 in (230 mm)

Other specifications

LV839064 — Other specifications
ParameterValue
Device short nameMTZ3 60 HF

Product details

The Schneider Electric LV839064 is a Masterpact MTZ3 60 HF switch disconnector rated for 6000 A at 104 °F (40 °C), built for distribution applications. It's a 3-pole fixed-mount unit with a push-button control type, designed for AC networks at 50/60 Hz. Breaking capacity hits 100 kA Icu at 254 V and 508 V AC, and 85 kA Icu at 635 V AC — all with an external relay per ANSI C37.50. That's serious fault-interruption headroom for a main distribution breaker in an industrial plant or large commercial building.

Physical footprint: 30.2 in wide, 13.9 in tall, 11.7 in deep. Connection pitch is 9.06 in (230 mm).

Rated operational current of 6000 A at 40 °C ambient — that's the continuous current the main contacts carry without exceeding temperature rise limits. In a real switchboard, that governs the busbar sizing and the ventilation requirement.

Frequently asked questions

What are the key ratings of LV839064?

Rated operational current is 6000 A at 40 °C. Breaking capacity is 100 kA Icu at 254 V and 508 V AC, and 85 kA Icu at 635 V AC with an external relay per ANSI C37.50. It's a 3-pole fixed-mount switch disconnector for AC distribution networks.

What are the physical dimensions of LV839064?

Width is 30.2 in (767 mm), height is 13.9 in (352.2 mm), depth is 11.7 in (297.1 mm). Connection pitch is 9.06 in (230 mm).

MPN