Schneider Electric LV839077 — Air Circuit Breakers

Schneider Electric LV839077 MasterPact MTZ3 4000A 3P Drawout

MPNLV839077
Active

Schneider Electric MasterPact MTZ3, LV839077, 3-pole drawout air circuit breaker, 4000 A rated at 40 °C, breaking capacity to 200 kA Icu at 254 V AC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839077 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839077 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839077 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)100 kA 0.5 s ANSI C37.50
Breaking capacity codeL1

Performance

LV839077 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50

Mechanical & connection

LV839077 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839077 is a MasterPact MTZ3 drawout air circuit breaker, 3-pole, rated 4000 A continuous at 40 °C. It ships without a Micrologic trip unit — the buyer selects the protection relay separately. The frame carries an breaking capacity code, which means 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, 150 kA at 508 V, and 100 kA at 635 V. That is the fault-clearing ceiling; the actual interrupting rating depends on the installed trip unit and system voltage. This is a main or large-feeder breaker for ANSI-style switchgear — not a panelboard or MCC bucket device. The drawout cradle lets you rack the breaker between connected, test, and disconnected positions without pulling cables, which is standard for maintenance and arc-flash mitigation in industrial and data-center distribution.

The 100 kA Icw for 0.5 s (ANSI C37.50) is the short-time withstand — the breaker can carry 100 kA symmetrical for half a second while downstream breakers clear a fault. That is the number that governs selective coordination: if your upstream transformer or generator can deliver 100 kA, this frame holds long enough for the feeder breaker to open. The integral instantaneous protection is set at 243–297 kA, which is an arc-flash mitigation band — it clears bolted faults in under 9 ms (the listed maximum break time) before the short-time delay expires. Mechanical endurance is 10,000 cycles, electrical endurance 1,000 cycles under rated load per ANSI C37.50. For a main breaker that operates a few times a year, that is effectively life-of-installation. For a generator or process breaker that cycles weekly, track the count.

Frequently asked questions

Does LV839077 include a trip unit?

No. The LV839077 is the frame and cradle only — it ships without a Micrologic trip unit. The buyer selects the protection relay separately based on the required curve, communication, and metering functions.