Skip to main content
Schneider Electric LV839088 — Air Circuit Breakers

LV839088 Masterpact MTZ3 32 HC 3200A 3P Switch Disconnector,

MPNLV839088
Active

Schneider Electric Masterpact MTZ3 32 HC, LV839088, switch disconnector, 3200 A, 3P, fixed, push-button control, 200 kA Icu at 254 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839088 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution
LV839088 — Electrical ratings
ParameterValue
Rated operational current (Ie)3200 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839088 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)100.0 kA 1.5 s ANSI C37.50
Breaking capacity200.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 200.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 130.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
LV839088 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Connection pitch9.06 in (230 mm)
LV839088 — Other specifications
ParameterValue
Device short nameMTZ3 32 HC

Product details

The LV839088 is a Schneider Electric Masterpact MTZ3 32 HC switch disconnector rated for 3200 A continuous at 104 °F (40 °C), 3-pole, fixed-mount, with push-button control. The breaking capacity is the headline number: 200 kA Icu at 254 V AC (50/60 Hz) with an external relay per ANSI C37.50, 200 kA at 508 V, and 130 kA at 635 V. The short-time withstand rating is 100 kA for 1.5 s (ANSI C37.50), which gives downstream breakers time to clear a fault selectively before this upstream device trips.

Physical footprint: 30.2 in (767 mm) wide, 13.9 in (352.2 mm) tall, 11.7 in (297.7 mm) deep. Fixed-mount design — no draw-out cradle, so the breaker is bolted directly into the switchboard bus. The connection pitch is 9.06 in (230 mm) between phase centers, which is standard for this class of air power breaker. Panel builders need to plan for the full depth clearance behind the door for arc-chamber venting and cable bending radius.

Frequently asked questions

Who supplies LV839088 and how is it quoted for volume purchases?

We supply the LV839088 against an RFQ. Availability and current pricing are confirmed at quote time — the part is a standard production item, so lead times are typical for a high-current air breaker of this class. Volume pricing is available on request.

What is LV839088's listed depth?

The LV839088 has a depth of 11.7 in (297.7 mm). This is the front-to-back dimension for enclosure planning and bus connection clearance.

What is LV839088's listed width?

The LV839088 has a width of 30.2 in (767 mm). This is the overall breaker width for switchboard compartment sizing.

MPN
LV839088