Schneider Electric LV839090 — Air Circuit Breakers

Schneider Electric LV839090 Masterpact MTZ3 40 HC, 4000A, 3P

MPNLV839090
Active

Schneider Electric Masterpact MTZ3 40 HC, switch disconnector, LV839090, 4000 A rated, 3P, fixed, 200 kA Icu at 254 V AC.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839090 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839090 — Electrical ratings
ParameterValue
Rated operational current (Ie)4000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839090 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)100.0 kA 1.5 s ANSI C37.50
Breaking capacity200.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 200.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 130.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50

Mechanical & connection

LV839090 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Width30.2 in (767 mm)
Height13.9 in (352.2 mm)
Depth11.7 in (297.7 mm)
Connection pitch9.06 in (230 mm)

Other specifications

LV839090 — Other specifications
ParameterValue
Device short nameMTZ3 40 HC

Product details

The Schneider Electric LV839090 is a Masterpact MTZ3 40 HC switch disconnector rated 4000 A at 104 °F (40 °C), 3-pole, fixed-mounted, intended for distribution applications. At 508 V AC the same configuration delivers 200 kA Icu, and at 635 V AC it holds 130 kA Icu, so the part handles the full low-voltage range common in North American industrial plants.

The 4000 A rated operational current (Ie) governs the continuous load it can carry — sized for a main feeder or large bus riser in a 480 V distribution switchboard. The 100 kA short-time withstand current (Icw) for 1.5 s per ANSI C37.50 tells you the breaker can pass that fault current without damage while downstream devices clear, supporting selective coordination schemes. Fixed mounting and push-button control suit it for drawout-free installations where the breaker stays bolted in place and is operated locally.

At 30.2 in (767 mm) wide, 13.9 in (352.2 mm) high, and 11.7 in (297.7 mm) deep, the LV839090 occupies a substantial footprint — plan for a dedicated compartment in the switchgear lineup. The 9.06 in (230 mm) connection pitch sets the bus-bar or cable landing spacing. Fixed mounting means the breaker does not require a drawout cradle, saving some enclosure depth but requiring direct wiring access.

Frequently asked questions

How do I get current pricing and availability for LV839090?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution. Submit an RFQ for a current quote and lead-time estimate.

What is LV839090's breaking capacity at 254 V AC?

The LV839090 delivers 200 kA Icu at 254 V AC 50/60 Hz with an external relay per ANSI C37.50, and 200 kA Icu at 508 V AC, 130 kA Icu at 635 V AC under the same conditions.

What are the physical dimensions of LV839090?

The LV839090 measures 30.2 in (767 mm) wide, 13.9 in (352.2 mm) high, and 11.7 in (297.7 mm) deep, with a connection pitch of 9.06 in (230 mm).