Schneider Electric LV839112 — Air Circuit Breakers

LV839112 MasterPact MTZ1 1600A 3P Fixed Circuit Breaker, 65

MPNLV839112
Active

Schneider Electric MasterPact MTZ1, LV839112, 1600 A rated, 3-pole, fixed-mount circuit breaker, H breaking capacity, 600 VAC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839112 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ1
ApplicationProtection

Electrical ratings

LV839112 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839112 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)35 kA 0.5 s UL 489
Breaking capacity codeH

Performance

LV839112 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.50 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50

Mechanical & connection

LV839112 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate Rails
Width10.9 in (276.2 mm)
Height11.8 in (300.5 mm)
Depth8.2 in (209 mm)
Connection pitch2.8 in (70 mm)

Product details

The Schneider Electric LV839112 is a MasterPact MTZ1 frame circuit breaker — UL 489 listed, 1600 A continuous at 40 °C, three-pole, fixed-mounted, with an H breaking capacity code. It ships without a Micrologic trip unit, so the buyer selects the protection curve separately. This is the bare frame and mechanism, intended for switchboard builders who integrate their own trip package. The interrupting ratings under UL 489 are 65 kA Icu at 240 V AC, 50 kA Icu at 480 V AC, and 50 kA Icu at 600 V AC — these are the fault-clearing limits the breaker guarantees at those voltages. The H code means it sits in the middle of the MTZ1 breaking range, above the standard (S) and below the extreme (L) tier, sized for most commercial and industrial distribution panels where 50–65 kA available fault current is the ceiling.

Durability and coordination data

Mechanical endurance is 10,000 cycles per ANSI C37.50; electrical endurance under load is 1,000 cycles per the same standard. That electrical figure governs maintenance intervals — after roughly 1,000 loaded operations at rated current, the arc chutes and contacts should be inspected. Total break time is 25–30 ms; maximum closing response is 50 ms. The integral instantaneous protection range spans 81–99 kA, meaning the magnetic trip element, if present in the installed trip unit, will operate without intentional delay when fault current exceeds that band.

Fixed-mount design on a base plate with rails. The mounting hole pitch is 70 mm (2.8 in). Overall dimensions: 11.8 in high, 10.9 in wide, 8.2 in deep. That depth includes the mechanism and arc chamber — panel depth must clear the full 209 mm behind the mounting plate. No DIN-rail clip; this bolts into a switchboard or enclosure floor.

Frequently asked questions

What are the UL 489 interrupting ratings for LV839112?

The LV839112 carries 65 kA Icu at 240 V AC, 50 kA Icu at 480 V AC, and 50 kA Icu at 600 V AC, all under UL 489. The H breaking capacity code places it in the mid-range of the MTZ1 family.

What is the rated current and temperature for LV839112?

The line rated current is 1600 A at 104 °F (40 °C). This is the continuous current the breaker can carry without exceeding its thermal limits, assuming proper enclosure ventilation.

Where can I buy LV839112 and how is it quoted?

The LV839112 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — no stock figures or price lists are published here.

Does LV839112 include a trip unit?

No. The LV839112 ships without a Micrologic trip unit. The buyer selects and installs the appropriate protection curve (LSIG, LSI, or electronic) separately based on the application's coordination study.