Schneider Electric LV839113

Schneider LV839113 MasterPact MTZ1 1600A 3P Fixed, 100kA Icu

MPN LV839113
Active

Schneider Electric MasterPact MTZ1 series, LV839113, 1600 A at 40 °C, 3-pole fixed-mount circuit breaker, breaking capacity, 100 kA Icu at 240 V AC, UL 489, without Micrologic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839113 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch2.8 in (70 mm)
Depth8.2 in (209 mm)
Width10.9 in (276.2 mm)
Height11.8 in (300.5 mm)
Electrical life cycles1000 cycles ANSI C37.50
Mechanical life cycles10000 cycles ANSI C37.50
ApplicationProtection
Safety category100 kA Icu 240 V AC 60 Hz UL 489 65 kA Icu 480 V AC 60 Hz UL 489

Product details

The LV839113 is a MasterPact MTZ1 frame circuit breaker rated 1600 A continuous at 40 °C (104 °F) — that is the full-frame current, not a derated value, so it carries a 1600 A bus or feeder without needing a larger frame. The breaking capacity code means 100 kA Icu at 240 V AC and 65 kA Icu at 480 V AC under UL 489, which covers most industrial service-entrance and distribution panel applications where fault current runs high. The 3-pole fixed-mount construction bolts onto a base plate with rails (70 mm connection pitch), so it lands in a switchboard or a dedicated enclosure — not a DIN-rail panel. No Micrologic trip unit ships with this order code; the buyer sources the trip unit separately to match the protection curve (LSIG, LSI, or electronic) needed for the downstream load.

Deployment context

Fixed-mount breakers like this one go into switchboards, motor control centers, or dedicated distribution enclosures — not DIN-rail cabinets. The 209 mm depth, 276 mm width, and 300 mm height mean the enclosure must allow front-access cable termination and sufficient clearance for arc-flash boundaries. The 70 mm pole-to-pole pitch matches standard bus-bar spacing for 1600 A class switchgear.

Performance and protection

Rated short-time withstand current (Icw) is 10 kA for 0.5 s under UL 489 — this breaker coordinates with downstream devices that clear faster than half a second, so it holds in during a fault without welding contacts. The integral instantaneous protection trips between 19.8 and 24.2 kA, which is the magnetic-only backup if the electronic trip unit is absent or fails. Maximum breaking time is 9 ms, and closing response is 50 ms. Mechanical endurance is 10,000 cycles, electrical endurance 1,000 cycles per ANSI C37.50 — typical for a primary distribution breaker that sees infrequent switching.

MPN
LV839113