Schneider Electric LV839144 — Air Circuit Breakers

LV839144 MasterPact MTZ2 3000 A 3P Drawout Circuit Breaker

MPNLV839144
Active

Schneider Electric MasterPact MTZ2, LV839144, UL 489 circuit breaker, 3000 A rated, 3-pole, drawout mount, H breaking capacity, 600 VAC, without Micrologic trip unit, with ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839144 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection

Electrical ratings

LV839144 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839144 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)65 kA 0.5 s UL 489
Breaking capacity codeH

Performance

LV839144 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839144 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV839144 is a MasterPact MTZ2 drawout circuit breaker rated 3000 A continuous at 40 °C, 3-pole, with an H breaking capacity code. That H code means it delivers 100 kA Icu at 480 V AC and 85 kA Icu at 600 V AC under UL 489 — which is the interrupting rating that governs whether this breaker clears a fault without blowing up upstream gear. The 65 kA Icw short-time withstand rating for 0.5 s (UL 489) tells you it can ride through a delayed trip coordination scheme, so you can build selective coordination downstream without losing the main. The drawout mounting means the breaker chassis stays bolted to the base plate rails while the mechanism slides in and out — no need to disconnect power cables for maintenance or swap-out. That's the kind of feature that keeps a line-down event under an hour instead of a shift. The integral instantaneous protection trips between 135 and 165 kA peak, and the maximum breaking time sits at 25 to 30 ms. That speed limits arc energy and lets the ArcBlok technology do its job — containing the arc inside the pole and reducing pressure buildup in the enclosure.

Where it sits in the panel

The drawout cradle mounts on base plate rails, with a 4.5 in (115 mm) connection pitch that matches standard bus-bar takeoff spacing. Physical footprint is 17.5 in wide by 17.3 in tall by 16.8 in deep — that's a substantial piece of iron, so plan the enclosure depth and bus-bar routing accordingly. The breaker ships without a Micrologic trip unit, so you'll select and install the appropriate electronic trip relay separately.

Frequently asked questions

How do I get current pricing and availability for LV839144?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time against your order quantity and delivery window.

What is LV839144's listed depth?

The listed depth is 16.8 in (426.8 mm).

What is LV839144's listed width?

The listed width is 17.5 in (444.3 mm).

What compliance documentation does this brand provide for LV839144?

The LV839144 carries a UL 489 listing per the product description, which covers the safety standard for molded-case circuit breakers. RoHS and REACH compliance documentation is typically available from the manufacturer upon request, though not listed in this record.

MPN
LV839144