Skip to main content
Schneider Electric LV839144

LV839144 MasterPact MTZ2 3000 A 3P Drawout Circuit Breaker

MPN LV839144
Active

Schneider Electric MasterPact MTZ2, LV839144, UL 489 circuit breaker, 3000 A rated, 3-pole, drawout mount, H breaking capacity, 600 VAC, without Micrologic trip unit, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839144 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch4.5 in (115 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection
Safety category100 kA Icu 240 V AC 50/60 Hz UL 489 100 kA Icu 480 V AC 50/60 Hz UL 489 85 kA Icu 600 V AC 50/60 Hz UL 489

Product details

The LV839144 is a MasterPact MTZ2 drawout circuit breaker rated 3000 A continuous at 40 °C, 3-pole, with an H breaking capacity code. That H code means it delivers 100 kA Icu at 480 V AC and 85 kA Icu at 600 V AC under UL 489 — which is the interrupting rating that governs whether this breaker clears a fault without blowing up upstream gear. The 65 kA Icw short-time withstand rating for 0.5 s (UL 489) tells you it can ride through a delayed trip coordination scheme, so you can build selective coordination downstream without losing the main. The drawout mounting means the breaker chassis stays bolted to the base plate rails while the mechanism slides in and out — no need to disconnect power cables for maintenance or swap-out. That's the kind of feature that keeps a line-down event under an hour instead of a shift. The integral instantaneous protection trips between 135 and 165 kA peak, and the maximum breaking time sits at 25 to 30 ms. That speed limits arc energy and lets the ArcBlok technology do its job — containing the arc inside the pole and reducing pressure buildup in the enclosure.

Where it sits in the panel

The drawout cradle mounts on base plate rails, with a 4.5 in (115 mm) connection pitch that matches standard bus-bar takeoff spacing. Physical footprint is 17.5 in wide by 17.3 in tall by 16.8 in deep — that's a substantial piece of iron, so plan the enclosure depth and bus-bar routing accordingly. The breaker ships without a Micrologic trip unit, so you'll select and install the appropriate electronic trip relay separately.

MPN
LV839144