Skip to main content
Schneider Electric LV839151

Schneider LV839151 MasterPact MTZ2 800A 3P Drawout Circuit B

MPN LV839151
Obsolete

Schneider Electric MasterPact MTZ2, LV839151, 800 A 3-pole drawout circuit breaker, L breaking capacity, 600 VAC, UL 489, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839151 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch4.5 in (115 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 240 V AC 50/60 Hz UL 489 150 kA Icu 480 V AC 50/60 Hz UL 489 100 kA Icu 600 V AC 50/60 Hz UL 489

Product details

It carries a 200 kA Icu at 240 V AC and 150 kA Icu at 480 V AC per UL 489 — the L-code indicates the highest interrupting rating in the MTZ2 frame, sized for large commercial and industrial mains. The ArcBlok technology contained inside limits arc energy during interruption, which reduces stress on downstream components and speeds fault clearing.

The 800 A frame rating sets the continuous current limit at 40 °C ambient — derate above that per the thermal curve. The 200 kA Icu at 240 V AC means this breaker can safely interrupt a fault up to 200,000 symmetrical amperes without external fusing; at 480 V the same rating drops to 150 kA, still well above typical service-entrance fault levels. The 30 kA Icw for 0.5 s gives short-time withstand for selective coordination downstream — the breaker holds in during a delayed trip to let a branch device clear first. Mechanical durability of 12,500 cycles and electrical durability of 2,800 cycles under ANSI C37.50 define the maintenance interval for drawout racking operations.

Drawout mounting means the breaker chassis is fixed to the panel base plate rails, and the removable cradle slides in and out for service without disturbing line or load connections. The 4.5 in (115 mm) connection pitch matches standard bus-bar spacing for switchgear assemblies. Overall dimensions: 17.5 in wide × 17.3 in tall × 16.8 in deep — verify the panel cutout and clearance for the racking mechanism before specifying.

MPN
LV839151