Schneider Electric LV839153 MasterPact MTZ2, 1600A, 3P, Draw

MPNLV839153
Active

Schneider Electric MasterPact MTZ2, LV839153, UL 489 circuit breaker, 1600 A rated, 3-pole, drawout mount, L breaking capacity, 600 VAC, with ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839153 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection

Electrical ratings

LV839153 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839153 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)30 kA 0.5 s UL 489
Breaking capacity codeL

Performance

LV839153 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839153 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV839153 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, UL 489 listed, rated 1600 A continuous at 104 °F (40 °C) across three poles. It's a protection device for large industrial feeders, switchboards, and main disconnects where high interrupting capacity and selective coordination are required. The L breaking capacity code means it delivers 200 kA Icu at 240 VAC, 150 kA Icu at 480 VAC, and 100 kA Icu at 600 VAC per UL 489 — enough to handle high-fault utility feeds without cascading upstream. The drawout cradle lets you rack the breaker out for safe maintenance or swap without disturbing line-side connections. Integral instantaneous protection is set at 72...88 kA, and the rated short-time withstand current (Icw) is 30 kA for 0.5 s per UL 489, which supports selective coordination downstream. Maximum breaking time is 9 ms — fast enough to limit let-through energy on a bus fault.

The LV839153 is a drawout breaker: it mounts into a fixed cradle with base plate rails (connection pitch 4.5 in / 115 mm). Overall dimensions are 17.5 in wide, 17.3 in high, 16.8 in deep. That depth includes the breaker body plus the drawout mechanism — account for the racking handle clearance in front of the panel. The cradle footprint is standard for MasterPact MTZ2 drawout; if you're retrofitting an older MT or NW cradle, verify the interface — the drawout alignment and secondary disconnect pinout changed on the MTZ2 generation.

Mechanical durability is rated 12,500 cycles per ANSI C37.50; electrical durability is 2,800 cycles under the same standard. For a main breaker that sees a few operations per day, that's decades of service. If your application requires frequent switching (e.g., capacitor bank or arc furnace duty), the mechanical endurance is the limit — the electrical endurance is lower because each interruption wears the contacts.

Frequently asked questions

What is LV839153's interrupting capacity?

The LV839153 has a breaking capacity code L, delivering 200 kA Icu at 240 VAC, 150 kA Icu at 480 VAC, and 100 kA Icu at 600 VAC per UL 489.

How do I get current pricing and availability for LV839153?

Submit an RFQ through this listing. We source the LV839153 through independent distribution and confirm current pricing and availability at quote time.