Skip to main content
Schneider Electric LV839163 — Air Circuit Breakers

Schneider LV839163 MasterPact MTZ2 800A 3P Drawout, 200kA Ic

MPNLV839163
Active

Schneider Electric MasterPact MTZ2, LV839163, 800 A, 3-pole, drawout, LF breaking capacity, 600 VAC, UL 489, with ArcBlok.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839163 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV839163 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839163 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)22 kA 0.5 s UL 489
Breaking capacity codeLF
LV839163 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50
LV839163 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The Schneider Electric LV839163 is a MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 800 A at 40 °C, with LF breaking capacity. It carries UL 489 listings at 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC — the Icu values tell you the maximum fault current it can safely interrupt at each voltage level, which governs the available fault current your system can tolerate upstream. The drawout cradle means the breaker can be racked out for maintenance or replacement without disturbing line-side connections, standard for switchgear lineups.

The integral instantaneous protection is set at 49.5 to 55.5 kA, meaning the breaker clears bolted faults above that threshold without intentional delay, which is typical for the LF (low-energy) breaking capacity variant.

Integration notes

Drawout mounting on base plate rails. The unit occupies a 17.5 in wide by 17.3 in tall by 16.8 in deep footprint (444.3 x 438.8 x 426.8 mm). Connection pitch is 4.5 in (115 mm) between phases. Mechanical durability is rated at 10,000 cycles per ANSI C37.50; electrical durability at 1,000 cycles under load — the gap reflects contact wear from arc interruption. Maximum breaking time is 9 ms, closing response time 70 ms, which matters for arc-flash incident energy calculations.

Frequently asked questions

Where can I buy LV839163 and how do I get a price?

We source the LV839163 to order against an RFQ through independent distribution. Submit a request for quote — availability and current pricing are confirmed at quote time. No stock figures or price lists are published for this obsolete part.

What breaking capacity does LV839163 have at 480 V?

The LV839163 is rated 150 kA Icu at 480 V AC 50/60 Hz per UL 489, meaning it can safely interrupt a fault current up to 150,000 symmetrical amperes at that voltage without external fusing.

What is the physical size of LV839163?

The drawout circuit breaker measures 17.5 in wide by 17.3 in tall by 16.8 in deep (444.3 x 438.8 x 426.8 mm), with a phase-to-phase connection pitch of 4.5 in (115 mm).

MPN
LV839163