Schneider Electric LV839166 — Air Circuit Breakers

Schneider LV839166 MasterPact MTZ2 2000A 3P Drawout, Obsolet

MPNLV839166
Active

Schneider Electric MasterPact MTZ2, LV839166, UL 489 circuit breaker, 2000 A rated, 3-pole, drawout mount, LF breaking capacity, 600 VAC, with ArcBlok.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839166 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV839166 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839166 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)22 kA 0.5 s UL 489
Breaking capacity codeLF
LV839166 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50
LV839166 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The Schneider LV839166 is a MasterPact MTZ2 drawout circuit breaker rated 2000 A at 104 °F (40 °C), 3-pole, with LF breaking capacity.

This part is obsolete per the manufacturer.

The 2000 A line-rated current at 40 °C sets the continuous ampacity for the drawout cassette and cradle — no derating needed at typical 40 °C ambient. The 150 kA Icu at 480 V AC UL 489 and 100 kA Icu at 600 V AC UL 489 define the interrupting capacity at those common distribution voltages; the LF breaking capacity code signals a high-interrupting variant for high-fault installations. Integral instant protection trips between 49.5 and 55.5 kA — that's the magnetic-only instantaneous pickup for short-circuit protection, not the long-time or short-time settings. The 22 kA Icw at 0.5 s UL 489 short-time withstand current tells you the breaker can hold closed under fault for 0.5 s to allow downstream coordination, then clear. Drawout mounting means the breaker slides into a cradle with disconnect position for safe maintenance without unbolting line and load connections. The 4.5 in (115 mm) connection pitch and base plate rails support define the footprint for switchboard integration.

Frequently asked questions

Where can I buy LV839166?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for LV839166?

2000 A rated current at 40 °C, 3-pole, drawout mount, with 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC per UL 489. Integral instant protection trips at 49.5 to 55.5 kA. Short-time withstand current is 22 kA for 0.5 s.

What is the depth of LV839166?

The depth is 16.8 in (426.8 mm).

What is the width of LV839166?

The width is 17.5 in (444.3 mm).