Skip to main content
Schneider Electric LV839201 — Air Circuit Breakers

LV839201 MasterPact MTZ2 1600A 3P Drawout Circuit Breaker, 2

MPNLV839201
Active

Schneider Electric MasterPact MTZ2, LV839201, 1600 A, 3-pole, drawout, L1F breaking capacity, 635 V AC, ANSI C37.50.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839201 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection

Electrical ratings

LV839201 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839201 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)22 kA 0.5 s ANSI C37.50
Breaking capacity codeL1F

Performance

LV839201 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50

Mechanical & connection

LV839201 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The Schneider Electric LV839201 is a MasterPact MTZ2 drawout circuit breaker rated for 1600 A continuous at 104 °F (40 °C), 3-pole, with an L1F breaking capacity code. It delivers 200 kA Icu at 254 V AC and 508 V AC, and 130 kA Icu at 635 V AC per ANSI C37.50 — that means it safely interrupts fault currents up to 200 kA at the lower voltages, which covers most large-service entrance and feeder applications in industrial and commercial power distribution. The drawout mounting lets you rack the breaker in and out of its cradle without unbolting line and load connections — a key feature for maintenance and quick swap-out in switchgear lineups. The ArcBlok technology is integrated to reduce arc flash energy during interruption.

The 1600 A frame is the CT rating and the continuous current at 40 °C — size your bus and cable for this ampacity. The short-time withstand current (Icw) is 22 kA for 0.5 s, which governs selectivity coordination with downstream breakers: you need upstream devices that can hold in for 0.5 s at 22 kA to let this breaker clear a fault selectively. Integral instantaneous protection trips between 49.5 and 55.5 kA — this is the magnetic-only pickup range for short-circuit protection. The maximum breaking time is 9 ms, and the closing response time is 70 ms max. Mechanical durability is 10,000 cycles; electrical durability is 1,000 cycles under ANSI C37.50 — plan maintenance intervals accordingly for frequent switching applications.

Physical Fit & Panel Integration

The drawout cradle mounts on base plate rails. Overall dimensions: 17.5 in wide (444.3 mm), 17.3 in high (438.8 mm), 16.8 in deep (426.8 mm). The connection pitch is 4.5 in (115 mm) — verify your bus bar or cable lug spacing matches this centerline before committing the switchgear layout.

Frequently asked questions

What is the breaking capacity of LV839201?

The LV839201 delivers 200 kA Icu at 254 V AC and 508 V AC, and 130 kA Icu at 635 V AC, all per ANSI C37.50. The short-time withstand current (Icw) is 22 kA for 0.5 s.

Where can I buy LV839201?

The LV839201 is available to order through our channel. Submit an RFQ for current pricing and availability — we confirm both at quote time.

MPN
LV839201