Schneider Electric LV839212 — Air Circuit Breakers

Schneider LV839212 MicroLogic 2.0 X Control Unit, MasterPacT

MPNLV839212
Active

Schneider Electric MasterPacT, MicroLogic 2.0 X control unit, LV839212, LI protection, LCD display, full power metering, 3P 4P.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839212 — Identification
ParameterValue
Product typeControl unit
RangeMasterPacT
ApplicationEquipment protection, monitoring and control

Electrical ratings

LV839212 — Electrical ratings
ParameterValue
Network typeAC
Network frequency50/60 Hz

Mechanical & connection

LV839212 — Mechanical & connection
ParameterValue
Mounting modeFixed

Environmental

LV839212 — Environmental
ParameterValue
Operating ambient temperature-13...158 °F (-25...70 °C) operating) -31 °F (-35 °C) for start-up of product)
Pollution degree3 IEC 60947-1
Operating altitude<= 16404.2 ft (5000 m) with operational voltage derating 560 V AC

Approvals

LV839212 — Approvals
ParameterValue
StandardsEN/IEC 60255-1 EN/IEC 60092-202 EN/IEC 60947-2 EN/IEC 60947-1

Product details

The Schneider Electric LV839212 is a MicroLogic 2.0 X control unit for the MasterPacT range of air circuit breakers.

The trip unit rating is configurable: 400 A, 630 A, 800 A, 1000 A, 1250 A, 1600 A, 2000 A, 2500 A, 3200 A, 4000 A, 5000 A, and 6300 A. The long-time pickup (Ir) is adjustable from 0.4 to 1 x In in 1 A steps. The instantaneous pickup (Ii) is adjustable, and the long-time delay (tr) has three settable curves: 12.5–600 s at 1.5 x Ir, 0.5–24 s at 6 x Ir, and 0.7–16.6 s at 7.2 x Ir. This gives you the selectivity headroom to coordinate downstream breakers without nuisance tripping on motor inrush. Metering accuracy is Class 0.5 for voltage and current, Class 1 for active power and energy, and Class 2 for reactive power and THD. That means the built-in power meter is accurate enough for submetering and energy allocation without a separate revenue-grade meter.

Metering and Diagnostics — What the LCD Tells You

The 128 x 96 pixel LCD display shows all metered values locally: phase and neutral currents, line-to-line and line-to-neutral voltages, active/reactive/apparent power, power factor, frequency, THD, and unbalance. The unit logs min/max values, alarms, events, and maintenance logs with time stamps. The diagnostics suite includes circuit breaker health state, contact wear, trip cause indication, protection test results, and selectivity test results. Thermal memory is standard, so the trip curve remembers the thermal history of the protected conductor after a momentary overload.

Communication and Connectivity

The control unit communicates via Bluetooth 4.0 LE (30 kbit/s), NFC (28.8 kbaud), and USB (115 kbaud). This allows local configuration and data download using a smartphone or laptop without opening the panel door. Measurement voltage input is 208–828 V AC phase-to-phase and 120–480 V AC phase-to-neutral, 50/60 Hz.

Rated for operation from -25 °C to +70 °C (start-up down to -35 °C), with 95% relative humidity at 55 °C per IEC 60068-2-30. EMC tested per IEC 61000-4-2/3/4/5/6 and CISPR 22 Class A.

Frequently asked questions

What is LV839212's listed poles (3P 4P) on this component line?

The LV839212 supports 3-pole and 4-pole MasterPacT breakers, with protected pole configurations including 3P 3d, 4P 3d, 4P 4d, 4P 3d + N/2, and 4P 3d + OSN.

What is LV839212's listed range (MasterPacT) on this component line?

The LV839212 is part of the Schneider Electric MasterPacT range of air circuit breakers.

What compliance documentation does this brand provide for LV839212 (RoHS, REACH, UL, IEC)?

The LV839212 is compliant with EN/IEC 60255-1, EN/IEC 60092-202 (marine applications), EN/IEC 60947-2, and EN/IEC 60947-1. EMC compliance covers IEC 61000-4-2/3/4/5/6 and CISPR 22 Class A.