Schneider Electric LV839216 — Air Circuit Breakers

Schneider Electric LV839216 MicroLogic 5.0 X Control Unit, M

MPNLV839216
Active

Schneider Electric MasterPacT, MicroLogic 5.0 X electronic control unit, LSI protection, LCD display, 4P 3d, trip unit rating 400…6300 A.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839216 — Identification
ParameterValue
Product typeControl unit
RangeMasterPacT
ApplicationEquipment protection, monitoring and control

Electrical ratings

LV839216 — Electrical ratings
ParameterValue
Network typeAC
Network frequency50/60 Hz

Mechanical & connection

LV839216 — Mechanical & connection
ParameterValue
Mounting modeFixed

Environmental

LV839216 — Environmental
ParameterValue
Operating ambient temperature-13...158 °F (-25...70 °C) operating) -31 °F (-35 °C) for start-up of product)
Pollution degree3 IEC 60947-1
Operating altitude<= 16404.2 ft (5000 m) with operational voltage derating 560 V AC

Approvals

LV839216 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 60947-2 EN/IEC 60092-202

Product details

The Schneider Electric LV839216 is a MicroLogic 5.0 X electronic control unit for MasterPacT air circuit breakers. It provides LSI protection — long-time, short-time, and instantaneous — plus integrated power and energy metering with a 128 x 96 pixel LCD display. The trip unit rating spans 400 A to 6300 A, so the same control unit fits across the MasterPacT frame range. The 4P 3d pole notation means the unit is wired for four poles but protects three — the fourth pole is a switched neutral without overload protection. This is the standard configuration for a 3-phase + neutral distribution board where the neutral is switched but not monitored for overcurrent. Other neutral protection settings are available (1 x Ir, 0.5 x Ir, 1.6 x Ir, or no protection) depending on the system grounding.

Protection and metering depth

The LSI protection functions cover overload (ANSI 49), instantaneous short-circuit (ANSI 50), and short-time short-circuit (ANSI 51). Long-time pickup is adjustable from 0.4 to 1 x In in 1 A steps, and the long-time delay is adjustable in 0.5 s increments. Zone selective interlocking (ZSI) is included, which allows multiple breakers in a cascade to communicate fault direction and speed up clearing while maintaining selectivity. Metering covers the full electrical network picture: phase and neutral currents, ground fault current, phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power and energy, power factor, frequency, demand values, and total harmonic distortion for both current and voltage. Accuracy is ±0.5% for current and voltage, ±1% for active power and energy, and ±2% for reactive power and energy. The measurement voltage range is 208…828 V AC phase-to-phase, 120…480 V AC phase-to-neutral at 50/60 Hz.

Communication and diagnostics

The control unit communicates via Bluetooth 4.0 LE (30 kbit/s), NFC (ISO 15963), and USB (115 kbaud). This allows local connection with a smartphone or laptop for configuration, data retrieval, and firmware updates without opening the panel door. The unit logs alarms, events, maintenance data, min/max values, and trip context — useful for post-fault analysis and predictive maintenance planning.

The LV839216 is certified to EN/IEC 60947-1, EN/IEC 60947-2 (circuit-breaker standard), EN/IEC 60255-1 (measuring relays), and EN/IEC 60092-202 (marine electrical installations). Relative humidity tolerance is 95% at 55 °C.

Frequently asked questions

How do I get current pricing and availability for LV839216?

The LV839216 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to receive current pricing and confirmed availability at quote time.

What does 4P 3P mean on the LV839216?

4P 3d means the unit has four poles but protects three — the fourth pole is a switched neutral without overload protection. This is the standard configuration for a 3-phase + neutral distribution board where the neutral is switched but not monitored for overcurrent.

What compliance documentation does Schneider provide for LV839216?

The LV839216 is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60255-1, and EN/IEC 60092-202. It meets EMC requirements including IEC 61000-4-2 through -4-6 and CISPR 22 Class A conducted and radiated emissions.

MPN
LV839216