Schneider LV839239 MX 2nd Opening Voltage Release, 12 V DC,

MPNLV839239
Obsolete

Schneider Electric, MasterPact MTZ, voltage release, LV839239, MX 2nd opening coil, 12 V DC, drawout mounting, 50 ms response.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839239 — Identification
ParameterValue
Product typeVoltage release
ApplicationControl
LV839239 — Mechanical & connection
ParameterValue
Mounting modeDrawout
LV839239 — Other specifications
ParameterValue
Response time50 ms +/- 10 % MasterPact MTZ1 50 ms +/- 10 % MasterPact MTZ2 50 ms +/- 10 % MasterPact MTZ3
Device short namesecond MX
Supply holding power4.5 W 4.5 VA
Voltage release typeOpening coil
Threshold tripping voltage0.7...1.1 Un
Coil voltage12 V DC

Product details

The Schneider LV839239 is an MX 2nd opening voltage release for MasterPact MTZ drawout breakers — a control accessory that trips the breaker on loss or application of control voltage. It's the second MX coil position, meaning the breaker already carries one MX; this one adds a separate shunt-trip path for a second independent signal (e.g., remote emergency stop or undervoltage protection from a different source). Rated for 12 V DC control with a 50 ms response time across all three MTZ frame sizes. Holding power is 4.5 W / 4.5 VA, and the trip threshold sits at 0.7...1.1 Un.

Schneider has marked the LV839239 as Obsolete. That means factory production has ended — no new-build units are coming off the line. For a BOM that calls out this exact order code, the only channel is the independent surplus and last-time-buy market.

Drawout mounting means this coil is designed for the MasterPact MTZ drawout cradle — it plugs into the secondary disconnect block, not a fixed-mounted breaker. If your installation uses a fixed MTZ (non-drawout), this part won't physically connect. The 50 ms response is the time from voltage removal to contact opening; it's consistent across all three MTZ frame sizes, so the same coil works in an MTZ1 panelboard or an MTZ3 switchgear lineup. The 12 V DC control circuit is the coil's operating voltage — verify your control transformer or DC supply delivers 12 V DC nominal. The 0.7...1.1 Un threshold means the coil drops out (trips the breaker) when the control voltage falls below about 8.4 V DC, and it resets (re-energizes) above about 13.2 V DC. That's a standard undervoltage-release characteristic, not a shunt trip that fires on a pulse.

Frequently asked questions

Where can I buy LV839239 and get a price?

We source the LV839239 to order against an RFQ through independent distribution. Submit a quote request; availability and current pricing are confirmed at quote time.

What is the LV839239's mounting mode?

Drawout — designed for the MasterPact MTZ drawout cradle, not fixed-mounted breakers.

What is the LV839239's response time?

50 ms ±10% across all MasterPact MTZ frame sizes — MTZ1, MTZ2, and MTZ3.