Schneider LV839304 MasterPact MTZ3 5000A 3P Drawout Circuit

MPNLV839304
Active

Schneider Electric MasterPact MTZ3, LV839304, UL 489 circuit breaker, 5000 A rated, 3-pole, drawout mount, L breaking capacity, 600 VAC, without Micrologic trip unit, with ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839304 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839304 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839304 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)100 kA 0.5 s UL 489
Breaking capacity codeL

Performance

LV839304 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)5000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50

Mechanical & connection

LV839304 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839304 is a MasterPact MTZ3 drawout circuit breaker rated for 5000 A continuous at 40 °C, 3-pole, with L breaking capacity code. The integral instant protection is set at 153...187 kA, which is the magnetic trip threshold for bolted faults; that range tells you the breaker clears fast on hard shorts without waiting for the trip unit. Maximum breaking time is 9 ms, and the closing response is 70 ms — both matter for arc-flash energy coordination studies.

Duty cycle and mechanical endurance

Electrical durability is rated at 1000 cycles under ANSI C37.50, mechanical durability at 5000 cycles. For a 5000 A frame, 1000 electrical operations is typical for the main breaker role — you are not cycling this daily like a motor-starter contactor. The 5000 mechanical cycles cover racking and test positions over the breaker's service life.

Frequently asked questions

What does the L breaking capacity code mean?

The L breaking capacity code indicates the standard interrupting rating level on the MasterPact MTZ3 frame, corresponding to the UL 489 values listed: 200 kA at 240 VAC, 150 kA at 480 VAC, 100 kA at 600 VAC.

Does LV839304 include a trip unit?

No, the LV839304 ships without a Micrologic trip unit. The trip unit must be ordered separately to match the required protection functions (LSIG, P, H, etc.).