Schneider Electric LV839305 — Air Circuit Breakers

LV839305 Masterpact MTZ3 40 HB, 4000 A, 3P Drawout

MPNLV839305
Active

Schneider Electric Masterpact MTZ3 40 HB, LV839305, automatic switch disconnector, 4000 A rated operational current, 3-pole, drawout, ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839305 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839305 — Electrical ratings
ParameterValue
Rated operational current (Ie)4000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839305 — Breaking & withstand capacity
ParameterValue
Breaking capacity200.0 kA Icu 240 V AC 50/60 Hz UL 489 150.0 kA Icu 480 V AC 50/60 Hz UL 489 100.0 kA Icu 600 V AC 50/60 Hz UL 489

Mechanical & connection

LV839305 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839305 is a Masterpact MTZ3 40 HB automatic switch disconnector rated 4000 A at 104 °F (40 °C) — that is the continuous current it carries without derating in a typical 40 °C ambient. For a main or tie breaker on a 4000 A bus, this is the frame size that matches the bus rating, not a derated step-down. Breaking capacity is 200 kA Icu at 240 V AC, 150 kA at 480 V, and 100 kA at 600 V per UL 489. Integral instant protection is rated 170 kA, meaning the magnetic trip element handles that level of short-circuit current without relying on the electronic trip unit alone. This is a selectivity and arc-flash coordination parameter — the breaker clears fast enough to let downstream devices ride through.

Drawout construction and panel integration

Drawout mounting means the breaker chassis stays bolted to the switchboard frame while the moving portion racks in and out. For a 4000 A main, this is the standard for maintenance isolation — you rack the breaker to the test or disconnected position without unbolting power cables. Chassis-mount support and a connection pitch of 9.06 in (230 mm) define the bus-bar centers and the cutout in the switchboard floor. Width 31.07 in, height 18.8 in, depth 16.8 in. Verify switchboard compartment depth before specifying.

Frequently asked questions

What is the breaking capacity of LV839305?

200 kA Icu at 240 V AC, 150 kA at 480 V, and 100 kA at 600 V, all per UL 489. Integral instant protection is rated 170 kA.

What are the physical dimensions of LV839305?

Width 31.07 in (789.1 mm), height 18.8 in (478.1 mm), depth 16.8 in (426.8 mm). Connection pitch is 9.06 in (230 mm).