Skip to main content
Schneider Electric LV839306 — Air Circuit Breakers

Schneider LV839306 Masterpact MTZ3 50 HB, 5000 A, 3P Drawout

MPNLV839306
Active

Schneider Electric Masterpact MTZ3 50 HB, automatic switch disconnector, LV839306, 5000 A rated, 3P drawout, 200 kA Icu at 240 V AC UL 489.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839306 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution

Electrical ratings

LV839306 — Electrical ratings
ParameterValue
Rated operational current (Ie)5000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839306 — Breaking & withstand capacity
ParameterValue
Breaking capacity200.0 kA Icu 240 V AC 50/60 Hz UL 489 150.0 kA Icu 480 V AC 50/60 Hz UL 489 100.0 kA Icu 600 V AC 50/60 Hz UL 489

Mechanical & connection

LV839306 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric LV839306 is a Masterpact MTZ3 50 HB automatic switch disconnector rated for 5000 A at 104 °F (40 °C), in a 3-pole drawout chassis configuration with ArcBlok arc-fault containment. Rated operational current of 5000 A means this breaker handles the main incoming feed for a large industrial distribution panel or a high-current bus riser — not a branch circuit, not a motor load center. The 3-pole form serves three-phase 50/60 Hz AC networks. Breaking capacity reaches 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC per UL 489 — that is the fault current it can safely interrupt without welding contacts or rupturing the arc chamber. For a 5000 A frame, those numbers mean it can sit at the service entrance behind a transformer rated for high available fault current.

Drawout mounting and panel fit

Drawout mounting means the breaker mechanism slides into a fixed cradle on the chassis — you can rack it out for maintenance or replacement without disconnecting the main bus bars. The chassis mount is specified for a 31.07 in (789.1 mm) wide by 18.8 in (478.1 mm) tall by 16.8 in (426.8 mm) deep envelope, with a 9.06 in (230 mm) connection pitch between phases. The drawout cradle and ArcBlok technology together mean this part is designed for switchgear lineup integration — not a standalone enclosure. Plan for the cutout and racking clearance in the gear layout before specifying.

Frequently asked questions

What are the key ratings for LV839306?

Rated operational current is 5000 A at 104 °F (40 °C). Breaking capacity is 200 kA Icu at 240 V AC, 150 kA Icu at 480 V AC, and 100 kA Icu at 600 V AC, all per UL 489. It is a 3-pole drawout switch disconnector for 50/60 Hz AC networks.

Where can I buy LV839306 and get current pricing?

We source the LV839306 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the physical size of LV839306?

Width is 31.07 in (789.1 mm), height is 18.8 in (478.1 mm), depth is 16.8 in (426.8 mm). The connection pitch between phases is 9.06 in (230 mm).

MPN
LV839306