Schneider Electric LV839308 — Air Circuit Breakers

LV839308 MasterPact MTZ3 3P Drawout 5000A H2 635VAC Circuit

MPNLV839308
Active

Schneider Electric MasterPact MTZ3, LV839308, 3-pole drawout ANSI circuit breaker, 5000 A rated current, H2 breaking capacity (85 kA Icu at 508 VAC), 635 VAC, without Micrologic trip unit, with ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839308 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839308 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839308 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH2

Performance

LV839308 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839308 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839308 is a MasterPact MTZ3 drawout circuit breaker rated 5000 A continuous at 40 °C — that's the full-frame current, not a derated number, so it handles a 5000 A bus without forced cooling. The H2 breaking capacity code delivers 85 kA Icu at 508 VAC (per ANSI C37.50), which covers most industrial secondary-distribution fault levels in North America. The 170 kA rated breaking and making capacity tells you it can close into and interrupt a bolted fault at that level, critical for coordination studies. The 85 kA short-time withstand (Icw) for 0.5 s means it holds through delayed trips downstream — selectivity headroom for a multi-level distribution scheme.

Deployment context

Drawout mounting on base plate rails means the breaker slides into a fixed cradle — no bolted bus connections to torque. That cuts swap time during maintenance or fault replacement to minutes, not hours. The 3-pole configuration suits 3-phase AC distribution in switchgear lineups. The 50/60 Hz network frequency covers both 60 Hz North American and 50 Hz global installations without a de-rate.

Frequently asked questions

What is the closest alternative to LV839308 in the MasterPact MTZ3 family?

The LV839308 is the 3-pole drawout 5000 A H2 variant without a Micrologic trip unit. The closest sibling would be the same frame with a different breaking capacity code (H1 or H3) or with an integrated trip unit — but the H2 code and bare-breaker configuration are specific to this order code. No pin-compatible alternative exists within the same frame; the trip unit is ordered separately.

What compliance documentation does Schneider Electric provide for LV839308?

The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. The breaker is designed to ANSI C37.50 standards as stated in the performance ratings. For full compliance declarations, request the manufacturer's documentation at quote time.