Schneider Electric LV839311 — Air Circuit Breakers

Schneider Electric LV839311 MasterPact MTZ3, 4000 A, 3P, Dra

MPNLV839311
Active

Schneider Electric MasterPact MTZ3, LV839311, 3-pole drawout circuit breaker, 4000 A at 104 °F (40 °C), H3 breaking capacity, 635 VAC, without Micrologic trip unit, with ArcBlok.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839311 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839311 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839311 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85 kA 0.5 s ANSI C37.50
Breaking capacity codeH3

Performance

LV839311 — Performance
ParameterValue
Breaking time, max.25...30 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50

Mechanical & connection

LV839311 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839311 is a MasterPact MTZ3 drawout circuit breaker rated for 4000 A continuous at 40 °C (104 °F). That 4000 A figure is the line-rated current — the breaker carries that load continuously without exceeding its thermal limits, per the datasheet. The H3 breaking capacity code means 100 kA Icu at 254 V and 508 V AC, 50/60 Hz per ANSI C37.50, and 85 kA Icu at 635 V. This is a 3-pole (3P) unit in drawout mount, meaning it slides into a cradle in the switchgear lineup — no hard wiring to the breaker itself, so you can rack it out for maintenance or replacement without de-energizing the bus. The drawout chassis mounts on base plate rails with a connection pitch of 9.06 in (230 mm). Note: the breaker ships without a Micrologic trip unit (per the description). That trip unit is ordered separately and plugs into the front — the breaker is just the power frame and ArcBlok arc chute. If you're replacing an existing MTZ3 frame, verify the trip unit model from your BOM.

Integration into the switchgear lineup

The breaker's short-time withstand rating (Icw) is 85 kA for 0.5 s per ANSI C37.50 — that's the current the breaker can carry for half a second while a downstream device clears a fault, without the breaker itself tripping or welding. That figure drives selective coordination: if your upstream transformer or feeder can deliver 85 kA for 0.5 s, this breaker holds in. Mechanical durability is 12,500 cycles; electrical durability is 2,800 cycles under ANSI C37.50 test conditions. For a main breaker that sees infrequent switching (maybe a few operations per year), that's essentially a lifetime mechanical rating. The 25–30 ms maximum breaking time and 70 ms maximum closing response time are the mechanical travel times — the actual arc extinction happens faster with ArcBlok.

Protection and application context

The device application is protection — this is a circuit breaker, not a disconnect switch. The integral instantaneous protection range is 171–209 kA, which is the magnetic trip threshold for the breaker frame itself (not the Micrologic trip unit, which is ordered separately). That range means the breaker's internal instantaneous element will clear faults above 171 kA without waiting for the trip unit. For a 4000 A main on a large industrial or data-center switchboard, that 170 kA figure is the ceiling for your available fault current study. The CT rating matches the line current at 4000 A.

Frequently asked questions

What are the physical dimensions of LV839311?

Width is 31.07 in (789.1 mm), height is 18.8 in (478.1 mm), depth is 16.8 in (426.8 mm). The connection pitch between phases is 9.06 in (230 mm).

Does LV839311 include a trip unit?

No. The LV839311 ships without a Micrologic trip unit. The trip unit is ordered separately and plugs into the front of the breaker frame.

What breaking capacity does the H3 code mean?

The H3 breaking capacity code means 100 kA Icu at 254 V and 508 V AC, 50/60 Hz per ANSI C37.50, and 85 kA Icu at 635 V AC.