Schneider Electric LV839314 — Air Circuit Breakers

Schneider Electric LV839314 Masterpact MTZ3 50 HF, 5000A Dra

MPNLV839314
Active

Schneider Electric Masterpact MTZ3 50 HF, LV839314, automatic switch disconnector, 5000 A rated operational current, 3-pole drawout, 100 kA Icu at 254 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839314 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution
LV839314 — Electrical ratings
ParameterValue
Rated operational current (Ie)5000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839314 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 1.5 s ANSI C37.50
Breaking capacity100.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 100.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 85.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
LV839314 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)
LV839314 — Other specifications
ParameterValue
Device short nameMTZ3 50 HF

Product details

The Schneider Electric LV839314 is an automatic switch disconnector from the Masterpact MTZ3 series, designated 50 HF. This is a 3-pole drawout unit rated for 5000 A at 40 °C, meaning it handles full continuous current in distribution switchgear without forced cooling. The 100 kA Icu at 254 V AC and 85 kA Icu at 635 V AC (with external relay, per ANSI C37.50) tell you the interrupting capacity for fault clearing — a key selectivity coordination figure for the main breaker position in a low-voltage switchboard. The drawout mounting means the breaker chassis slides into a cradle with disconnect positions for test and isolated — no need to unbolt line/load conductors for maintenance. The chassis support is a fixed frame; the moving portion is the breaker itself. Connection pitch is 9.06 in (230 mm) between phase centers, which dictates bus bar take-off spacing in the switchgear lineup. Push-button control on the front fascia handles local open/close operations. The [Icw] rated short-time withstand current of 85 kA for 1.5 seconds confirms this breaker can carry fault current through the delayed trip coordination window — essential for zone-selective interlocking in large distribution systems.

Physical dimensions: the unit measures 31.07 in (789.1 mm) wide, 18.8 in (478.1 mm) high, and 16.8 in (426.8 mm) deep. These are the overall envelope dimensions for the drawout cradle assembly — verify the switchgear cell opening matches before specifying.

Frequently asked questions

Where can I buy LV839314 and how is it quoted?

The LV839314 is sourced to order through independent industrial distribution. Submit an RFQ for current pricing and availability confirmation — no stock count or price is published here.

What is the breaking capacity of LV839314?

The LV839314 is rated 100 kA Icu at 254 V AC, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC, all 50/60 Hz with external relay per ANSI C37.50. The short-time withstand current is 85 kA for 1.5 seconds.

MPN
LV839314