Schneider Electric LV839314 — Air Circuit Breakers

Schneider Electric LV839314 Masterpact MTZ3 50 HF, 5000A Dra

MPNLV839314
Active

Schneider Electric Masterpact MTZ3 50 HF, LV839314, automatic switch disconnector, 5000 A rated operational current, 3-pole drawout, 100 kA Icu at 254 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV839314 — Identification
ParameterValue
Product typeSwitch disconnector
ApplicationDistribution
LV839314 — Electrical ratings
ParameterValue
Rated operational current (Ie)5000 A 104 °F (40 °C)
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839314 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)85.0 kA 1.5 s ANSI C37.50
Breaking capacity100.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 100.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 85.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
LV839314 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The Schneider Electric LV839314 is an automatic switch disconnector from the Masterpact MTZ3 series, designated 50 HF. This is a 3-pole drawout unit rated for 5000 A at 40 °C, meaning it handles full continuous current in distribution switchgear without forced cooling. The 100 kA Icu at 254 V AC and 85 kA Icu at 635 V AC (with external relay, per ANSI C37.50) tell you the interrupting capacity for fault clearing — a key selectivity coordination figure for the main breaker position in a low-voltage switchboard. The drawout mounting means the breaker chassis slides into a cradle with disconnect positions for test and isolated — no need to unbolt line/load conductors for maintenance. The chassis support is a fixed frame; the moving portion is the breaker itself. Connection pitch is 9.06 in (230 mm) between phase centers, which dictates bus bar take-off spacing in the switchgear lineup. Push-button control on the front fascia handles local open/close operations. The [Icw] rated short-time withstand current of 85 kA for 1.5 seconds confirms this breaker can carry fault current through the delayed trip coordination window — essential for zone-selective interlocking in large distribution systems.

Physical dimensions: the unit measures 31.07 in (789.1 mm) wide, 18.8 in (478.1 mm) high, and 16.8 in (426.8 mm) deep. These are the overall envelope dimensions for the drawout cradle assembly — verify the switchgear cell opening matches before specifying.

Frequently asked questions

Where can I buy LV839314 and how is it quoted?

The LV839314 is sourced to order through independent industrial distribution. Submit an RFQ for current pricing and availability confirmation — no stock count or price is published here.

What is the breaking capacity of LV839314?

The LV839314 is rated 100 kA Icu at 254 V AC, 100 kA Icu at 508 V AC, and 85 kA Icu at 635 V AC, all 50/60 Hz with external relay per ANSI C37.50. The short-time withstand current is 85 kA for 1.5 seconds.

MPN