Skip to main content
Schneider Electric LV846160

Schneider LV846160 MasterPact MTZ2 800A 3P 100kA Breaker

MPN LV846160
Active

Schneider Electric MasterPact MTZ2, LV846160, 800 A rated current, 3-pole, 100 kA breaking capacity at 440 V AC, fixed mount, IP30.

$3,402.27 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846160 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846160 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV846160 is a MasterPact MTZ2 air circuit breaker rated 800 A at 40 °C, 3-pole, with a 100 kA ultimate breaking capacity (Icu) at 440 V AC. For a Category B breaker (per EN/IEC 60947-2), this makes it suitable for selective coordination in a main or tie position where downstream devices clear before the main trips. The short-time withstand (Icw) is 100 kA for 0.5 s and 1 s, and 75 kA for 3 s — this is the current the breaker can carry without damage while a downstream breaker clears a fault. The making capacity (Icm) is 220 kA at 440 V AC, which covers the asymmetrical peak current during closure onto a fault. These ratings, combined with the 12 kV impulse withstand (Uimp), confirm the breaker is designed for high-fault industrial distribution where arc-flash energy and coordination studies govern the specification.

Fixed-mount design, 422 mm wide × 352 mm high × 300 mm deep. Mounts on rails or a base plate. Connection pitch is 115 mm. Both front and rear connection are available on the upside and downside, giving panel builders flexibility in busbar routing and cable entry. The IP30 enclosure degree protects against tools and wires larger than 2.5 mm — adequate for indoor switchgear but not for washdown areas.

Also complies with IEC 61557-12 for power metering. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating.

MPN