LV846161 MasterPact MTZ2 3P 1000A Circuit Breaker, 100 kA

MPNLV846161
Active

Schneider Electric MasterPact MTZ2, 3-pole fixed circuit breaker, 1000 A rated current, 100 kA breaking capacity at 440 V AC, H2V performance level, IP30.

$3,706.83Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV846161 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846161 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Sensor rating400 A 630 A 800 A 1000 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846161 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846161 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation70 W
LV846161 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportRails Base plate
Width422 mm
Height352 mm
Depth300 mm
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846161 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846161 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV846161 is a MasterPact MTZ2 3-pole fixed circuit breaker rated 1000 A at 40 °C, with a 100 kA ultimate breaking capacity (Icu) at 440 V AC. That 100 kA figure is the same as its service breaking capacity (Ics) at that voltage — meaning after clearing a fault at full rating, the breaker is still usable without derating, not a one-shot device. It's a Category B breaker per IEC 60947-2, which means it's designed with intentional short-time delay for selectivity — you can coordinate it downstream of a larger breaker so only the faulted branch opens, not the whole switchboard. The 100 kA short-time withstand (Icw) for 1 second confirms it can hold that current through a delayed trip without welding contacts. Rated insulation voltage is 1000 V AC. Impulse withstand is 12 kV.

Fixed-mount chassis, 422 mm wide by 352 mm tall by 300 mm deep. Connection pitch is 115 mm on the busbars. Top and bottom connections can be front or rear — that's a field choice during install, not a factory option you have to lock in at order time. Mounts on rails or a base plate; the fixed format means you're bolting it into a switchboard, not pulling it out on a cradle. IP30 protection — that's finger-safe from the front but not sealed. It expects to live inside an enclosure, not out in a washdown area.

Current production. The MasterPact MTZ2 platform is Schneider's active high-end air breaker line.

Frequently asked questions

What is LV846161's breaking capacity at 440 V?

The LV846161 has a 100 kA ultimate breaking capacity (Icu) and 100 kA service breaking capacity (Ics) at 440 V AC, 50/60 Hz. The making capacity (Icm) is 220 kA at that voltage.

What standards does the LV846161 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2.