Skip to main content
Schneider Electric LV846162

Schneider LV846162 MasterPact MTZ2 1250A 3P Circuit Breaker,

MPN LV846162
Active

Schneider Electric MasterPact MTZ2, fixed circuit breaker, 3P, 1250 A at 40 °C, H2V 100 kA at 415 V AC, push-button control, without control unit.

$4,037.85 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846162 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846162 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider LV846162 is a MasterPact MTZ2 fixed-mount circuit breaker, 3-pole, rated 1250 A at 40 °C. It belongs to the H2V performance tier — 100 kA ultimate breaking capacity (Icu) at 440 V AC, 50/60 Hz, and the same 100 kA service breaking (Ics). That means it clears a fault up to 100 kA and stays functional afterward, no immediate replacement needed. Category B selectivity (per EN/IEC 60947-2) lets it coordinate with downstream breakers so only the faulted branch trips — critical for a production line where you want the main breaker to hold while a feeder clears. Rated operational voltage is 440 V AC, insulation voltage 1000 V AC, impulse withstand 12 kV. Short-time withstand (Icw) holds 100 kA for 0.5 s and 1 s, 75 kA for 3 s — enough for selective coordination with downstream devices. Mounting is fixed on rails or base plate, connection pitch 115 mm. Both upside and downside connections accept front or rear terminations — common in switchboard builds where cable routing differs between incoming and outgoing sections. IP30 protection; inside a panel that's fine, but keep it out of direct washdown zones.

Also meets IEC 61557-12 for insulation monitoring. Isolation suitability is confirmed per EN/IEC 60947-2 — the breaker provides visible isolation when open. Altitude derating above 2000 m is specified, so check if your installation is above that.

MPN