Schneider Electric LV846173 — Air Circuit Breakers

Schneider Electric LV846173 MasterPact MTZ2 1600 A Circuit B

MPNLV846173
Active

Schneider Electric MasterPacT MTZ2, LV846173, 3P drawout circuit breaker, 1600 A at 40 °C, H2V 100 kA at 415 V AC, IP30.

$5,349.51Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV846173 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846173 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Sensor rating800 A 1000 A 1250 A 1600 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846173 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846173 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation390 W
LV846173 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
Width441 mm
Height439 mm
Depth403 mm
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846173 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846173 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The Schneider Electric LV846173 is a MasterPact MTZ2 drawout circuit breaker rated 1600 A at 40 °C, with a 100 kA ultimate breaking capacity (Icu) at 440 V AC. The 100 kA service breaking capacity (Ics) at the same voltage tells you it can reclose after a fault at full rating, not just survive it once. This is a Category B breaker, meaning it's designed with intentional short-time delay for selective coordination — you can set it to ride through downstream faults so only the nearest device opens, keeping the rest of the plant online. The 100 kA short-time withstand (Icw) for 1 second backs that up: it holds the fault current for the coordination interval without damage. The drawout mounting means the breaker chassis stays wired in the switchgear; the removable cradle lets you rack the breaker out for maintenance or replacement without disturbing the power connections. Front and rear connection options give flexibility for cable or busbar entry in new builds or retrofits.

Integration — what fits in the footprint

The drawout cradle mounts on rails or a base plate. Overall dimensions: 441 mm wide, 439 mm high, 403 mm deep. IP30 protection is typical for enclosed switchgear — the breaker is not intended for open-panel or washdown environments.

Frequently asked questions

What are the key ratings of LV846173?

Rated current 1600 A at 40 °C, ultimate breaking capacity (Icu) 100 kA at 440 V AC, service breaking capacity (Ics) 100 kA at 440 V AC, rated insulation voltage 1000 V AC, and short-time withstand (Icw) 100 kA for 1 second.

What compliance documentation does this brand provide for LV846173?

The breaker complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is certified for isolation per EN/IEC 60947-2.

MPN