Skip to main content
Schneider Electric LV846173

Schneider Electric LV846173 MasterPact MTZ2 1600 A Circuit B

MPN LV846173
Active

Schneider Electric MasterPacT MTZ2, LV846173, 3P drawout circuit breaker, 1600 A at 40 °C, H2V 100 kA at 415 V AC, IP30.

$5,349.51 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846173 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846173 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width441 mm
Height439 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV846173 is a MasterPact MTZ2 drawout circuit breaker rated 1600 A at 40 °C, with a 100 kA ultimate breaking capacity (Icu) at 440 V AC. The 100 kA service breaking capacity (Ics) at the same voltage tells you it can reclose after a fault at full rating, not just survive it once. This is a Category B breaker, meaning it's designed with intentional short-time delay for selective coordination — you can set it to ride through downstream faults so only the nearest device opens, keeping the rest of the plant online. The 100 kA short-time withstand (Icw) for 1 second backs that up: it holds the fault current for the coordination interval without damage. The drawout mounting means the breaker chassis stays wired in the switchgear; the removable cradle lets you rack the breaker out for maintenance or replacement without disturbing the power connections. Front and rear connection options give flexibility for cable or busbar entry in new builds or retrofits.

Integration — what fits in the footprint

The drawout cradle mounts on rails or a base plate. Overall dimensions: 441 mm wide, 439 mm high, 403 mm deep. IP30 protection is typical for enclosed switchgear — the breaker is not intended for open-panel or washdown environments.

MPN