Skip to main content
Schneider Electric LV846186

LV846186 MasterPact MTZ2 3200 A Circuit Breaker, 100 kA

MPN LV846186
Active

Schneider Electric MasterPacT MTZ2, LV846186, fixed 4P circuit breaker, 3200 A at 40 °C, H2V 100 kA at 415 V AC, EN/IEC 60947.

$13,759.72 – $14,611.32 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846186 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846186 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846186 is a MasterPact MTZ2 fixed-mount circuit breaker rated 3200 A at 40 °C with an H2V performance class delivering 100 kA breaking capacity at 415 V AC. The 4-pole configuration with neutral on the left is standard for 3-phase + N distribution. Category B selectivity means it's designed for full discrimination with downstream breakers, so a fault on a branch won't take the main bus down — that's the difference between a nuisance plant blackout and a localized trip. Short-time withstand Icw is 100 kA for 1 second, giving you real coordination headroom for downstream devices with longer trip delays. Rated impulse withstand voltage Uimp is 12 kV, covering typical surge environments in industrial switchgear.

Fixed-mount design — this is a bolted-in switchgear breaker, not a draw-out cassette. It mounts on rails or a base plate inside a distribution cabinet. Dimensions: 537 mm wide, 352 mm high, 300 mm deep. That 300 mm depth is the dimension you need for enclosure depth planning — make sure the gland plate and busbar clearance behind the breaker can accommodate it. Connection pitch is 115 mm, which matters for busbar drilling patterns. Upside and downside connections both accept front or rear termination, giving flexibility for cable or busbar entry in the cabinet layout.

Also listed to IEC 61557-12 for measuring equipment in LV systems. Electrical durability is rated at 5000 cycles at In under AC-23A conditions; mechanical durability is 15,000 cycles with periodic preventive maintenance. Power dissipation is 420 W at rated current — factor that into enclosure ventilation calculations.

MPN
LV846186